Do not turn off power immediately after the unit stops,
NOTE
but wait for at least 5 minutes.
Adjusting the air flow direction
(See figure 6) (only for CS-20~125LM, CS-20~125UM,
CS-25~63DM)
Press the air flow direction button to select the air direction.
1
The air flow flap display swings as shown below
and the air flow direction continuously varies.
(Automatic swing setting.)
Press the air flow direction adjust button to select
the air direction of your choice.
The air flow flap display stops swinging and the
air flow direction is fixed. (Fixed air flow direction
setting.)
Movement of the air flow flap
For the following conditions, a micro computer controls the air flow
direction which may be different from the display.
COOLING
When the room temperature is lower
than the set temperature
When operating continuously at horizontal air flow direction
The air flow direction can be adjusted in one of the following ways.
I
The air flow flap itself adjusts its position.
I
The air flow direction can be fixed by the user.
Automatic
and desired position
I
NOTE
The movable limit of the flap is changeable. Contact
your Panasonic dealer for details. (Only for
CS-20~125LM, CS-20~125UM, CS-25~63DM)
Avoid operating in the horizontal direction
may cause dew or dust to settle on the ceiling.
Programming start and stop of the system with timer
(See figure 9)
The timer is operated in the following two ways.
I
-
Programming the stop time
operating after the set time has elapsed.
-
Programming the start time
operating after the set time has elapsed.
I
The timer can be programmed for a maximum of 72 hours.
The start and the stop time can be simultaneously programmed.
I
Press the timer mode start/stop button several times and select
1
the mode on the display. The display flashes.
-
For setting the timer stop
-
For setting the timer start
Press the programming time button and set the time for
2
stopping or starting the system.
When this button is pressed, the time advances
by 1 hour.
When this button is pressed, the time goes
backward by 1 hour.
Operation manual
4
(See figure 13)
HEATING
When the room temperature is
lower than the set temperature
At defrost operation
.
. It
. The system stops
. The system starts
Press the timer on/off button.
3
The timer setting procedure ends. The display
changes from flashing light to constant light.
NOTE
When setting the timer off and on at the same
I
time, repeat the above procedure (from
) once again.
3
After the timer is programmed, the display shows
I
the remaining time.
Press the timer on/off button once again to cancel
I
programming. The display vanishes.
For example: (See figure 11)
When the timer is programmed to stop the system
after 3 hours and start the system after 4 hours, the
system will stop after 3 hours and start 1 hour later.
Setting the master remote controller
(See figure 10)
When the system is installed as shown in figure 14, it is
I
necessary to designate one of the remote controllers as the
master remote controller.
Only the master remote controller can select heating or cooling.
I
The displays of slave remote controllers show
I
(changeover under control) and they automatically follow the
operation mode directed by the master remote controller.
However, it is possible to changeover to program dry with slave
remote controllers if the system is in cooling operation set by the
master remote controller.
How to designate the master remote controller
Press the operation mode selector button of the current master
1
remote controller for 4 seconds.
The display showing
slave remote controllers connected to the same outdoor unit
flash.
Press the operation mode selector button of the controller that
2
you wish to designate as the master remote controller. Then
designation is completed. This remote controller is designated
as the master remote controller and the display showing
(changeover under control) vanishes.
The displays of other remote controllers show
(changeover under control).
Precautions for group control system or two remote
controller control system
This system provides two other control systems beside individual
control (one remote controller controls one indoor unit) system.
Confirm the following if your unit is of the following control system
type.
I
Group control system
One remote controller controls up to 16 indoor units. All indoor
units are equally set.
Two remote controller control system
I
Two remote controllers control one indoor unit (in case of group
control system, one group of indoor units). The unit is
individually operated.
Contact your Panasonic dealer in case of changing the
NOTE
combination or setting of group control and two remote
controller control systems.
or
to
1
(changeover under control) of all
CU-5~10MX1SPP
Urban Multi air conditioner
4PW12337-1