Please note that the pins have to be properly positioned according to the column in which they are
placed.
REMINDER:
Keys with red pins = active keys
Keys with blue pins = inactive keys
VERY IMPORTANT:
All "rectangular" recesses have to be turned
outward from the casing.
Once this operation is finished, replace the plate ensuring the good position of all springs.
Check the good operation (keyboard, lock, latch...) before installing the assembly on the door.
REMINDER:
ALWAYS START BY PRESSING "C" BUTTON BEFORE ENTERING THE CODE, then no order
in the numbering is requested.
Once the modifications made, write down the new code.
4. INSTALLATION OF THE FLUSH-MOUNTED LOCK:
See the manufacturer instructions for installing the flush-mounted lock.
5. INSTALLING THE HANDLES
1 - Verify the dimension of the "square" of your lock: It is of 7mm or 8mm.
For a 7mm square: you have to use the "k" adapter.
For an 8 mm square: you have to use the "j" adapters.
2 - Place the template from the page 1 and drill the 2 "p" holes for assembling the 2 parts (keypad
bloc and handle block).
3 - Place the 2 parts front to front assembling them with the "d" long guide and put the 2 blocks
against the door. If the guide used is too long, repeat the operation with the "e" medium guide or
the "f" short guide, if necessary.
5EN