Instruction Leaflet IL040029EN
PowerXL DH1 Series VFD
Instruction Leaflet
Montageanweisung
Notice d'installation
Instrucciones de montaje
Istruzioni per il montaggio
en
Electric Current! Danger to Life!
Only skilled or instructed persons may carry out the following operations.
de
Lebensgefahr durch elektrischen Strom!
Nur Elektrofachkräfte und elektrotechnisch unterwiesene Personen
dürfen die im Folgenden beschriebenen Arbeiten ausführen.
fr
Tension électrique dangereuse !
Seules les personnes qualifiées et averties doivent exécuter les
travaux ci-après.
es
¡Corriente eléctrica! ¡Peligro de muerte!
El trabajo a continuación descrito debe ser realizado por personas
cualificadas y advertidas.
it
Tensione elettrica: Pericolo di morte!
Solo persone abilitate e qualificate possono eseguire le operazioni di
seguito riportate.
zh
Электрический ток! Опасно для жизни!
ru
Только специалисты или проинструктированные лица могут
выполнять следующие операции.
Инструкция по монтажу
Montagehandleiding
Montagevejledning
Οδηγίες εγκατάστασης
Instruções de montagem
Monteringsanvisning
Effective December 2017
Supersedes March 2014
Asennusohje
Návod k montáži
Paigaldusjuhend
Szerelési utasítás
Montāžas instrukcija
Montavimo instrukcija
nl
Levensgevaar door elektrische stroom!
Uitsluitelijk deskundigen in elektriciteit en elektrotechnisch
geinstrueerde personen is het toegestaan, de navolgend
beschrevene werkzaamheden uit te voeren.
da
Livsfare på grund af elektrisk strøm!
Kun uddannede el-installatører og personer der e instruerede i
elektrotekniske arbejdsopgaver, må udføre de nedenfor anførte
arbejder.
Προσοχή, κίνδυνος ηλεκτροπληξίας!
el
Οι εργασίες που αναφέρονται στη συνέχεια θα πρέπει να εκτελούνται
μόνο από ηλεκτρολόγους και ηλεκτροτεχνίτες.
pt
Perigo de vida devido a corrente eléctrica!
Apenas electricistas e pessoas com formação electrotécnica podem
executar os trabalhos que a seguir se descrevem.
sv
Livsfara genom elektrisk ström!
Endast utbildade elektriker och personer som undervisats i
elektroteknik får utföra de arbeten som beskrivs nedan.
fi
Hengenvaarallinen jännite!
Vain pätevät sähköasentajat ja opastusta saaneet henkilöt saavat
suorittaa seuraavat työt.
Instrukcja montażu
Navodila za montažo
Návod na montáž
Монтажни инструкции
Instrucţiuni de montaj
EATON
www.eaton.com
1

Publicité

loading

Sommaire des Matières pour Eaton PowerXL DH1 VFD Série

  • Page 1 Endast utbildade elektriker och personer som undervisats i Электрический ток! Опасно для жизни! elektroteknik får utföra de arbeten som beskrivs nedan. Только специалисты или проинструктированные лица могут выполнять следующие операции. Hengenvaarallinen jännite! Vain pätevät sähköasentajat ja opastusta saaneet henkilöt saavat suorittaa seuraavat työt. EATON www.eaton.com...
  • Page 2 от специалисти-електротехници и инструктиран електротехнически персонал. Tik elektrikai ir elektrotechnikos specialistai gali atlikti žemiau aprašytus darbus. Atenţie! Pericol electric! Toate lucrările descrise trebuie efectuate numai de personal de specialitate calificat şi de persoane cu cunoştiinţe profunde în electrotehnică. EATON www.eaton.com...
  • Page 3 205 = 205A, 150HP, 110KW 261 = 261A, 200HP, 132KW 310 = 310A, 250HP, 160KW IP00 FR7 and FR8 is not avaliable for 230V input product or with the PowerXL DH1 Product IP20 FR0 will be avalible in June 2018 EATON www.eaton.com...
  • Page 4 154.32 (888.5) (753.0) (707.0) (288.0) (282.0) (220.0) (220.0) (9.0) (70.0) (340.7) 14.61 40.75 33.27 31.38 19.13 18.90 15.75 15.75 0.35 246.91 (371) (1035) (845) (797) (486) (480) (400) (400) (112) Note FR0 is not available till June 2018. EATON www.eaton.com...
  • Page 5 Minimum clearances A and B for drives with Type 12 (IP54) enclosure is 0 mm (in) for FR1, FR2, FR3, FR4, FR6. The above guidelines apply unless testing has been completed to validate a design outside of these recommendations. FR0 is not available till June 2018. EATON www.eaton.com...
  • Page 6 M4*10 screw SCREW: 2-M4*10 SCREW: 2-M4*8flat SCREW: 2-M4*15 Output cable Magnetic ring Cable tie Input power wires Input grounding wire Note FR0 is not available till June 2018. EATON www.eaton.com...
  • Page 7 FR2 mounting instructions FR3 mounting instructions Step 1: Step 1: Step 2: Step 2: Screw: Four M5x15 or 3/16 inch Screw: Four M6x15 Nut: Four M5 or 1/4 inch or 3/16 inch Nut: Four M6 or 1/4 inch EATON www.eaton.com...
  • Page 8 Instruction Leaflet IL040029EN PowerXL DH1 Series VFD Effective December 2017 FR4 mounting instructions Step 1: Step 2: Screw: Four M8x15 or 3/8 inch Nut: Four M8 or 3/8 inch EATON www.eaton.com...
  • Page 9 PowerXL DH1 Series VFD Instruction Leaflet IL040029EN Effective December 2017 FR5 mounting instructions Step 1: Step 3: Step 2: Step 4: Screw: Four M8x20 or 3/8 inch Nut: Four M8 or 3/8 inch EATON www.eaton.com...
  • Page 10 (refer to the drive mounting template printed on the outside carton). SCREW:4-M8*20 NUT:4-M8 Step 2: Remove the four screws (used to fix the drive to the pallet) with an M8 or 3/8-inch wrench. Use a hook to lift the drive. Step 3: EATON www.eaton.com...
  • Page 11 Kytke vain jännitteettömässä tilassa! Varování! Připojujte jen při zcela odpojeném napájení! Ground wiring (FR1–FR4) No. 2 Phillips (FR5) No. 3 Phillips (FR1–FR3) M4, 10 in-lb (1.1 Nm) (FR4) M4, 14 in-lb (1.6 Nm) (FR5) M6, 35 in-lb (4.0 Nm) (FR1–FR3) (FR4–FR6) EATON www.eaton.com...
  • Page 12 Instruction Leaflet IL040029EN PowerXL DH1 Series VFD Effective December 2017 Rubber grommet installation instructions Step 1: Step 5: D1 (Cable) Step 2: D2 (Grommet) Step 6: Step 3: ≤ ≤ D1 + 2 mm Self-Locking Cable Ties Step 4: EATON www.eaton.com...
  • Page 13 35 (4.0) 4.5 (0.5) Notes Strip the motor and power cables as shown above. ® Both UL and IEC tools may be used. Applies to strained wire, solid wire, or ferrule installations. FR0 is not available till June 2018. EATON www.eaton.com...
  • Page 14 Earthing conductor size is determined by the maximum overcurrent device rating used ahead of the drive according to UL 508C Table 6.4. If power cubes or bypass are used, a UL listed Class RK5, J, T or equivalent fuse is recommended. FR0 is not available till June 2018. EATON www.eaton.com...
  • Page 15 Earthing conductor size is determined by the cross-sectional area of phase conductors according to IEC/EN 61800-5-1:2007 Table 5. So if phase conductor size is changed, earthing conductor size should also be changed accordingly. If power cubes or bypass are used, a Class gG/gL fuse is recommended. FR0 is not available till June 2018. EATON www.eaton.com...
  • Page 16 Earthing conductor size is determined by the maximum overcurrent device rating used ahead of the drive according to UL 508C Table 6.4. If power cubes or bypass are used, a UL listed Class RK5, J, T or equivalent fuse is recommended. FR0 is not available till June 2018. EATON www.eaton.com...
  • Page 17 Earthing conductor size is determined by the cross-sectional area of phase conductors according to IEC/EN 61800-5-1:2007 Table 5. So if phase conductor size is changed, earthing conductor size should also be changed accordingly. If power cubes or bypass are used, a Class gG/gL fuse is recommended. FR0 is not available till June 2018. EATON www.eaton.com...
  • Page 18 Earthing conductor size is determined by the maximum overcurrent device rating used ahead of the drive according to UL 508C Table 6.4. If power cubes or bypass are used, a UL listed Class RK5, J, T or equivalent fuse is recommended. EATON www.eaton.com...
  • Page 19 PowerXL DH1 Series VFD Instruction Leaflet IL040029EN Effective December 2017 EATON www.eaton.com...
  • Page 20 IP Modbus TCP Optional Card A Optional Card B Control I/O Terminals RS-485 Terminating Resistor Removable MOV Screw Removable EMC Screw Motor Ground Clamp Location Line Ground Clamp Location Grounding Strap Location Grounding Strap Location Line Side Motor EATON www.eaton.com...
  • Page 21 24 V to CMA and CMB and close the inputs to ground. When using the +10 V for AI1, it is important to wire AI1—to ground (as shown by dashed line). If using +10 V for AI1 or AI2, terminals 3, 5, and 6 need to be jumpered together. AI1+ and AI2+ block that it can support 10K potentiometer. EATON www.eaton.com...
  • Page 22 DIN7 DIN8 DI5 DI8 +24 Vdc 100mA 24Vo +24Vdc 100mA AO1+ 0-60Hz 4-20mA AO2+ 0-FLA (4-20mA) 24Vi +24VDC DIN1 DIN2 DIN3 DIN4 DI1 DI4 RS-485 Modbus BACnet RS-485 Modbus BACnet R3NO R1NC R1CM R1NO R3CM R2NC R2CM R2NO EATON www.eaton.com...
  • Page 23 PowerXL DH1 Series VFD Instruction Leaflet IL040029EN Effective December 2017 EATON www.eaton.com...
  • Page 24 εφόσον διαπιστωθεί ότι το μηχάνημα πληροί τις απαιτήσεις προστασίας της οδηγίας της ΕΚ για τα μηχανήματα 89/392/ΕΟΚ. Κατασκευή σύμφωνα με τις απαιτήσεις ΗΜΣ. Εγκαθιστάτε τους αγωγούς ελέγχου και δικτύου ανεξάρτητα από τον αγωγό του κινητήρα. Συνδέετε τη θωράκιση των αγωγών σε μεγάλη επιφάνεια με τη γείωση. EATON www.eaton.com...
  • Page 25 že stroj spĺňa ochranné ustanovenia smernice č. 89/392/EHS площади. o strojových zariadeniach. Montáž v súlade s požiadavkami elektromagnetickej kompatibility. Ovládacie a siet˙ové vedenia uložte v priestore oddelene od vedenia motora. Zabezpečte veľkú kontaktnú plochu medzi káblovým tienením a PE. EATON www.eaton.com...
  • Page 26 The wire size range and tightening torque for field wiring terminals Warning! are presented. When two or more motors are connected to the inverter, they cannot be protected by the electronic overload protection. Install an external thermal relay on each motor. Technical support contact information EATON www.eaton.com...