Figure 98. Installing a power supply unit
Next steps
1. If you have unlatched the cable management arm, relatch it. For information about the cable management arm, see the system's rack
documentation at www.dell.com/poweredgemanuals.
2. Connect the power cable to the PSU, and plug the cable into a power outlet.
CAUTION:
When connecting the power cable to the PSU, secure the cable to the PSU with the strap.
NOTE:
When installing, hot swapping, or hot adding a new PSU, wait for 15 seconds for the système to recognize the
PSU and determine its status. The PSU redundancy may not occur until discovery is complete. Wait until the new
PSU is discovered and enabled before you remove the other PSU. The PSU status indicator turns green to signify
that the PSU is functioning properly.
Retrait d'un bloc d'alimentation secteur connecté non
redondant
Prérequis
1. Suivez les consignes de sécurité répertoriées dans la section
2. Suivez la procédure décrite dans la section
3.
Retirez le carénage à air
4. Débranchez le système de la prise secteur.
5. Débranchez tous les câbles reliant le PSU à la carte système.
6. Le cas échéant,
retirez la carte de montage pour carte d'extension.
Étapes
1. À l'aide d'un tournevis Phillips n° 2, retirez la vis fixant le PSU au système.
2. Faites glisser le PSU pour le retirer de son bâti.
Instructions de
Avant une intervention à l'intérieur du
sécurité.
système.
Installation et retrait des composants du système
129