Advanced Settings; Overview Advanced Settings; Transmitter Settings; Infrared Photocells Settings - LiftMaster myQ SL400EVK Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. PROGRAMMING

7.7 Advanced Settings

Herewith you start with Advanced Settings.

7.7.1 Overview Advanced Settings

LED
tr
r1
r2
r3
i1
i2
i3
Pd
tC
rt
EL

7.7.2 Transmitter Settings

Transmitter function defines how Transmitter commands are working.
Note: Under settings "01", "02" and "03", TTC timer will be overridden
by a transmitter command and will CLOSE the gate.
Under setting "04", active TTC timer countdown will be re-set to start
again by Transmitter command.
Residential Mode: Open – Close – Open
Standard Mode: Open – Stop – Close – Stop – Open (Default)
Automatic with Stop Mode: Open – Stop – Close – Open
Car Park Mode: Open, to complete Open position. Additional com-
mand during the opening will be ignored

7.7.3 Infrared Photocells Settings

IR functions define functioning mode of Infrared Photocells (IR).
IRs will be auto-learned when installed.
Each of the 3 IR sets can be programmed individually.
NOTE: Depending on the chosen settings the Partial Opening inputs or Remote
Controls commands will not be executed in both OPEN or CLOSE direction if the
IR beam is obstructed.
If IRs are removed, the control board power must be turned OFF/ON for two times
to unlearn.
For check and maintenance of the photocells see the manual of the photocells.
Function
Transmitter
IR1 photocell
IR2 photocell
IR3 photocell
Input 1 command
Input 2 command
Input 3 command

Partial Opening

Timer To Close (TTC)

Reversal time after impact

E-lock
LED
FL
PF
SP
St
Cn
PS
F1
F2
S1
S2
SF
Fd
FE
IR active on CLOSE movement. If IR beam is obstructed, gate re-
verses in complete OPEN position (Default).
IR active on OPEN movement. If IR beam is obstructed gate stops.
When obstruction disappears the gate continues to OPEN.
IR is active on OPEN and CLOSE movement. If IR beam is obst-
ructed on CLOSE movement, gate stops and after the obstruction
disappears gate reverses in complete OPEN position. If IR beam
is obstructed on OPEN movement, gate stops. When obstruction
disappears the gate continues to OPEN.
IR active on CLOSE movement. If IR beam is obstructed, gate re-
verses in complete OPEN position. The activated TTC function will
be overridden 2 seconds after the beam obstruction is eliminated
and will start CLOSE movement not waiting till the end of TTC time
end.

7.7.4 Input Settings

Inputs function define the way Input commands from external accessories are
executed. Each of the 3 Inputs can be programmed individually.
NOTE: Under settings "01", "02" and "03", TTC timer will be overridden by an Input
command and will CLOSE the gate. Under setting "06", active TTC timer count-
down will be re-set to start again by an Input command
13
Function
Flashing Light
Pre-Flashing
Special contact
START Speed in OPEN and CLOSE
Maintenance counter
Password (This menu is only available after the
Learning phase was finished.)
Force Motor in Open (protected by PS)
Force Motor in Close (protected by PS)
Speed Motor in OPEN (protected by PS)
Speed Motor in CLOSE (protected by PS)
SOFT-STOP Speed in OPEN and CLOSE
(protected by PS)
Factory default
Finish and Exit

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Myq sl600evkMyq sl1000evk

Table des Matières