CLEAN UP, LUBRICATION & MAINTENANCE
STEP ONE:  
CLEAN UP INSTRUCTIONS
NOTE: Proper sprayer clean up is critical to maintaining optimum performance. Dried
by-products act like glue and will cause moving parts to stick. Failure to properly clean your
sprayer will cause damage to the unit. Taking the time to clean your sprayer immediately
after use will help it last longer and work correctly. If you are finished with the project or are
not going to use the sprayer within the day you must follow these instructions for proper
clean up. Never store the sprayer longer than 30 minutes without cleaning.
1. Unplug your sprayer from the electrical outlet.
2. Empty any remaining (stain or paint) material from the container.
3. Fill container approximately 1/2 full with appropriate cleaning solution. For latex, use warm
soapy water; for oil-based, use a cleaning solution recommended by the material manufacturer.
4. Plug the sprayer into an electrical outlet.
5. Press the sprayer switch until the cleaning solution passes through the spray nozzle for
several seconds. See Figure G.
6. Unplug the sprayer from the electrical outlet.
7. Remove container and properly discard the cleaning solution.
STEP TWO:  
CLEAN UP INSTRUCTIONS FOR THE CYLINDER HOUSING
1. Unplug your sprayer from the electrical outlet.
2. Unscrew container, pull out pick-up tube.
3. Release cylinder locking knob. See Figure H.
4. Remove spray tip, atomizer valve, cylinder housing, piston spring,
and piston and clean thoroughly with cleaning solution and cleaning brush.
See Figure I.
5. Lubricate all moving parts with lightweight oil (included, or use WD40
3-in-One
oil, or similar product).
®
6. Reassemble all parts. Replace the cylinder locking knob.
7. Reassemble the pick-up tube and the container.
LUBRICATION INSTRUCTIONS
Lubricating the sprayer prior to storage is extremely important
to maximize the life of the cylinder housing and its components.
1. Unplug your sprayer from the electrical outlet.
2. Empty any remaining (stain or paint) material from the container,
remove the pick-up tube and clean.
3. Plug the sprayer into the electrical outlet.
4. Turn the sprayer upside down and squeeze a small amount
of petroleum oil into the pick-up tube port and the return port
(the one adjacent to the pick-up tube port). See Figure J.
5. Press the switch of the sprayer for three to five seconds while the sprayer is still turned
upside down. This will force the petroleum oil onto the piston and will protect the sprayer
from drying and the piston from seizing.
6. Turn the sprayer right side up and reinstall the pick-up tube and container.
7. Unplug your sprayer from the electrical outlet. Store the unit.
AIRLESS SPRAYERS PRO 5.0 and 5.5
,
®
Atomizer
Valve
Spray Tip
Cylinder
Housing
Piston
Spring
Piston
ENGLISH    9