Connection To Water Supply - Interpump Group TSX Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
4.1 HIGH PRESSURE CONNECTION
1 - Connect one end of the high pressure hose to the automatic gun (A) and the other end to
the OUTLET connection on the machine. Tighten firmly (B).
2 - Complete the assembly by coupling the extension to the gun/lance and tighten firmly (C).
4.2 - CONNECTION TO THE WATER SUPPLY
1- The maximum temperature of the inlet water must not exceed 60°C (140°F).
2- Connect the water supply to the INLET (D) port by means of a reinforced hose (min.15
bar/200 psi) with the internal diameter not less than 13mm (1/2")
3- Since the water flow decreases according to the length of the hose, make sure that the quan-
tity of water supplied to the machine is not less than the quantities indicated in the chart below.
4- The pressure of the inlet water must not exceed 10 bar.
FLOW RATE OF
TSX SERIES
WATER SUPPLY
MODEL
L/min.
TSX 10-130
TSX 12-100
15
TSX 12-140
TSX 951
TSX 14-120
TSX 13-180
17
TSX 954
TSX 956
TSX 15-150
TSX 17-130
20
TSX 957
TSX 961
IMPORTANT
The water supplied to the machine must be clean. Running the unit without water, or with water
which is dirty, contains grit or corrosive liquids, causes serious damage to the machine.
G.P .M. USA
OUTLET
4
4.5
5.3
B
D
INLET
16
C
A
ø 13 mm.