Siemens SITRANS TSinsert Instructions De Service page 48

Capteurs de température
Masquer les pouces Voir aussi pour SITRANS TSinsert:
Table des Matières

Publicité

Caractéristiques techniques
9.5 Précision de mesure pour thermocouples
Versions catalogue
Type
N
333 °C ... 1100 °C ±0,0075x|t[°C]|
(631 °F ... 2012 °F ±0.0075x|t[°F]-32|)
K
333 °C ... 1000 ℃ ±0,0075x|t[°C]|
(631 °F ... 1832 °F ±0.0075x|t[°F]-32|)
J
333 °C ... 750 °C ±0,0075x|t[°C]|
(631 °F ... 1382 °F ±0.0075x|t[°F]-32|)
Autres thermocouples, communs
Type
T
133 ℃ ... 350 ℃ ±0,0075x|t[°C]|
(271 °F ... 662 °F ±0.0075x|t[°F]-32|)
E
333 °C ... 900 °C ±0,0075x|t[°C]|
(631 °F ... 1652 °F ±0.0075x|t[°F]-32|)
Autres thermocouples, nobles
Type
R,S
600 °C ... 1600 °C ±0,0025x|t[°C]|
(1112 °F ... 2912 °F ±0.0025x|t[°F]-32|)
B
600 °C ... 1700 ℃ ±0,0025x|t[°C]|
(1112 °F ... 3092 °F ±0.0025x|t[°F]-32|)
48
Précision de base, classe 2
-40 °C ... +333 °C ±2,5 °C
(-40 °F ... +631 °F ±4.5 °F)
-40 °C ... +333 °C ±2,5°C
(-40 °F... +631 °F ±4.5 °F)
-40 °C ... +333 ℃ ±2,5 ℃
(-40 °F ... +631 °F ±4.5 °F)
Précision de base, classe 2
-40 °C ... +133 °C ±1 °C
(-40 °F ... +271 °F ±1.8 °F)
-40 °C ... +333 °C ±2,5°C
(-40 °F... +631 °F ±4.5 °F)
Précision de base, classe 2
0 °C ... 600 °C ±1,5 °C
(32 °F ... +1112 °F ±2.7 °F)
Précision accrue, classe 1
-40 °C ... +375 ℃ ±1,5 ℃
(-40 °F ... +707 °F ±2.7 °F)
375 °C ... 1000 °C ±0,004x|t[°C]|
(707 °F ... 1832 °F ±0.004x|t[°F]-32|)
-40 °C ... +375 ℃ ±1,5 ℃
(-40 °F... +707 °F ±2.7 °F)
375 °C ... 1000 °C ±0,004x|t[°C]|
(707 °F ... 1832 °F ±0.004x|t[°F]-32|)
-40 °C ... +375 °C ±1,5 °C
(-40 °F ... +707 °F ±2.7 °F)
375 °C ... 750 °C ±0,004x|t[°C]|
(707 °F ... 1382 °F ±0.004x|t[°F]-32|)
Précision accrue, classe 1
-40 °C ... +125 °C ±0,5 °C
(-40 °F ... +257 °F ±0.9 °F)
125 °C ... 350 °C ±0,004x|t[°C]|
(257 °F ... 662 °F ±0.004x|t[°F]-32|)
-40 °C ... +375 °C ±1,5 °C
(-40 °F... +707 °F ±2.7 °F)
375 °C ... 800 °C ±0,004x|t[°C]|
(707 °F ... 1472 °F ±0.004x|t[°F]-32|)
Précision accrue, classe 1
0 ℃ ... 1100 ℃ ±1 ℃
(32 °F ... +2012 °F ±1.8 °F)
1100 °C ... 1600 °C ±[1 + 0,003 x(t -1100)] °C
(2012 °F ... 2912 °F ±1,8+0,003x(t[°F]-2012)
-
SITRANS TSinsert/TS100/TS200/TS500
Instructions de service, 01/2013, A5E31627896-03

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sitrans ts100Sitrans ts200Sitrans ts500

Table des Matières