Dometic Waeco DC-Kit2 Instructions De Montage Et De Service page 40

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
Using the DC kit
 CA2500
If the charging voltage regulator cuts the connection to the supply battery
due to low voltage, it switches off the compressor in the roof air condi-
tioner at the same time. The inverter remains active and has voltage in
its socket.
As soon as the voltage in supply battery has reached the switch-on point
in the charging current distributor, the compressor in the roof air condi-
tioner switches on again.
If the voltage in the supply battery drops further and goes below the
10.5 V switch-off point for the inverter, the inverter switches off (chapter
"Driving mode: power supply from the 12 V battery with motor
switched off" on page 39).
 B2200, B1600 Plus, FJ1100, FJ1700, FJ2200, FL1600, FL2200
If the charging voltage regulator cuts the connection to the supply battery
due to low voltage, it switches off the roof air conditioner at the same
time. The inverter remains active and has voltage in its socket.
As soon as the voltage in supply battery has reached the switch-on point
in the charging current distributor, the roof air conditioner switches on
again.
If the voltage in the supply battery drops further and goes below the
10.5 V switch-off point for the inverter, the inverter switches off (chapter
"Driving mode: power supply from the 12 V battery with motor
switched off" on page 39).
 B1600
If the charging voltage regulator cuts the connection to the supply battery
due to low voltage, it switches off the inverter at the same time using the
FB2 remote control. There is no voltage in the socket for the inverter.
As soon as the voltage in the supply battery reaches the switch-on point
in the charging current distributor, it restores the connection between the
starter and supply battery and switches the inverter on again using the
FB2 remote control. There is voltage in the socket again for the inverter.
The air conditioning starts again automatically.
If the voltage in the supply battery drops further and goes below the
10.5 V switch-off point for the inverter, the inverter switches off (chapter
"Driving mode: power supply from the 12 V battery with motor
switched off" on page 39).
40
DC-Kit2
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dc-kit2

Table des Matières