Guarantee

The status LED (fig. 1 2, page 3) displays the following conditions:
Display
Green, constantly lit
Red, quickly flashing
Red, slowly flashing
Red, occasionally flashing
Red, constant light
11
Guarantee
The statutory warranty period applies. If the product is defective, please re-
turn it to the WAECO branch in your country (see the back of the instruction
manual for the address) or to your dealer. For repair and guarantee process-
ing, please include the following documents when you send in the appliance:
A copy of the receipt with purchasing date
A reason for the claim or description of the fault
12

Disposal

➤ If possible, always take the packaging material for recycling.
If you wish to finally dispose of the device, ask your local recycling
centre or specialist dealer for details about how to do this in accord-
ance with the applicable disposal regulations.
30
Cause
The device is functioning.
Input voltage is too high.
The input voltage is too low.
Overheating
Short circuit or electrical wir-
ing error
Excessive load
SinePower
Remedy
Check the input voltage.
Reduce the input voltage.
Charge the battery.
Check cables and contacts.
Ensure better ventilation.
Make certain that the ventila-
tion slots are not covered.
Lower the ambient tempera-
ture.
Check electrical wiring.
Reduce the load.