6

Fastening the inverter

You can fasten the inverter using the four holders supplied.
When selecting the installation location, observe the following instructions:
The inverter can be mounted horizontally or vertically.
The inverter must be installed in a place that is protected from moisture.
The inverter may not be installed in the presence of flammable materials.
The inverter may not be installed in a dusty environment.
The place of installation must be well-ventilated. A ventilation system
must be present for installations in small, closed spaces. The minimum
clearance around the inverter must be at least 25 cm (fig. 1, page 3).
The air intake on the underside or the air outlet on the back side of the
inverter must remain clear.
For ambient temperatures higher than 40 °C (such as in engine or heating
compartments, or direct sunlight), the heat from the inverter under load
can lead to the automatic shut-off of the inverter.
The installation surface must be level and sufficiently strong.
Caution
a
Before drilling any holes, ensure that no electrical cables or other
parts of the vehicle can be damaged by drilling, sawing and filing.
Fasten the inverter as follows (fig. 3, page 4):
➤ Clip two holders on the lower left bar and two on the right.
You can move the holders as required.
➤ Fasten the inverter by screwing one screw through each hole in the
holders.
Fastening the inverter