1. General Information

Assembly and installation should only be carried out by
qualified personnel
1.1 Uses
The submersible motor-driven pump is suitable for transporting
waste water, sewage, sludge and pure liquids from shafts, pits
and containers. It can be installed in sewage treatment plants, for
example, or used for pumping flooded rooms and ditches. It can
be assemble for use as a stationary or portable pump.
The pump must not be used for transporting drinking water.
1.2 Product data
1.2.1 Rating plate
Series: TP = Submersible motor-driven pump
Nominal width of pressure support [mm] 80, 100, 150
Type of impeller: E = single channel impeller
M = multiple channel impeller
F = impeller (VORTEX)
Nominal diameter of impeller [mm]
Power P2 [kW] = Value/ 10
1.2.2 Connection and electrical data
– Permissible components of the flow media:
– Mildly acidic / mildly alkaline,
– Maximum chloride content 400 mg/l,
– Additions (6-20%) of mineral oils / grease by mixing.
– Permission for the transport of waste water containing
chemicals should be obtained from WILO.
– maximum temperature of the medium: 40°C
– Explosion protection:
for P2 ≤ 3,4 kW:
for P2 ≥ 3,9 kW:
– Power supply
– Mains frequency:
– System of protection:
– Speed
– Type of operation:
Switching rate:
– power input P1:
– rated motor power P2:
– Max. flow rate:
– Max. lift:
– Flange connection:
Inlet and outlet pressure gland: TP 80 F: DN 80 / DN 80
– Completely free passage:
Max. immersion depth:

2. Safety

These instructions contain important information which must be
followed when installing and operating the pump. These
operating instructions must therefore be read before assembly
and commissioning by the installer and the responsible operator.
Both the general safety instructions in the "Safety precautions"
section and those in subsequent sections indicated by danger
symbols should be carefully observed.
8
TP 100 E 180 / 52
EEx de IIB T4
EEx d IIB T4
3 ~ 400 V, ±10 %
50 Hz
IP 68
max. 1450 tr/min
Continual mode S1
60 / h
see rating plate
see rating plate
see rating plate
see rating plate
PN 10 / 16
TP 80 E: DN 100 / DN 80
TP
100: DN 100 / DN 100
TP
150: DN 125 / DN 150
TP 80:
80 mm
TP 100:
80 mm / 100 mm
TP 150: 100 mm
20 m
2.1 Danger symbols used in these operating instructions
Safety precautions in these operating instructions which, if not
followed, could cause personal injury are indicated by the
symbol:
when warning of electrical voltage with
The following symbol is used to indicate that by ignoring the
relevant safety instructions, damage could be caused to the
pump/machinery and its functions:
ATTENTION!
2.2 Staff training
The personnel installing the pump must have the appropriate
qualifications for this work.
2.3 Risks incurred by failure to comply with the safety
precautions
Failure to comply with the safety precautions could result in
personal injury or damage to the pump or installation. Failure to
comply with the safety precautions could also invalidate any
claim for damages.
In particular, lack of care may lead to problems such as:
– Failure of important pump or machinery functions,
– Personal injury due to electrical, mechanical and bacterio-
logical causes.
2.4 Safety precautions for the operator
Existing regulations for the prevention of accidents must be
followed.
Dangers caused by electrical energy are to be excluded.
Directives issued by the VDE [German Association of Electrical
Engineers] and the local electricity supply companies are to be
observed.
Personal injury due to mechanical or bacteriological causes.
Local regulations and directives of the municipal sewage system
and the Waste Water Association (ATV) are to be followed.
2.5 Safety information for inspection and assembly
The operator is responsible for ensuring that inspection and
assembly are carried out by authorised and qualified personnel
who have studied the operating instructions closely.
In principle, work should not be carried out on a running pump
or installation and a second person should always be present.
2.6 Unauthorized modification and manufacture
of spare parts
Alterations to the pump or installation may only be carried out
with the manufacturer's consent. The use of original spare parts
and accessories authorised by the manufacturer will ensure
safety. The use of any other parts may invalidate claims invoking
the liability of the manufacturer for any consequences.
2.7 Unauthorised operating methods
The operating safety of the pump or installation supplied can only
be guaranteed if it is used in accordance with paragraph 1 of the
operating instructions. The limiting values given in the catalogue
or data sheet must neither be exceeded nor allowed to fall below
those specified.