Operating instructions SATAminijet 4400 B RP/HVLP
6.4. Use In Explosive Areas
Ex-sign
Equipment cat-
egory
6.4.1 General
The spray gun is approved for the use / storage in explosive areas of Ex-
Zone 1 and 2.
• The following applications and operations lead to the loss
of the explosion protection and are, therefore, prohibited:
• Use of the spray gun in explosive areas belonging to ex-zone 0!
• Do not use solvents and cleaning agents based on halogenized
hydrocarbons! Chemical reaction which may occur when using these
substances may be explosive!
7.

Use

• Use only solvent-resistant, antistatic, undamaged and technically
flawless compressed air hoses with a permanent pressure resistance
of minimum 10 bar / 145 psi, e.g. Art. No. 53090!
The following requirements must be fulfilled:
• Use of a compressed air connection G 1/4 a or of a fitting SATA con-
nection nipple.
• Ensure minimum compressed air volume (air consumption) and pres-
sure (recommended spray gun inlet pressure) according to chapter 2.
• Use clean compressed air, e.g. by installing the SATA filter 484, Art.
No. 92320
Device category
Danger! Risk of explosion!
Danger! Risk of explosion!
Information!
Gas category
US
Temperature
classification