Commands
Control Description
ERST ?
Error Status inquiry
LAMP ?
Lamp Status inquiry
INST ?
Input Source List inquiry
NAME ?
Projector Name inquiry
Manufucturer's Name
INF1 ?
INF2 ?
Model Name inquiry
INFO ?
Other Information inquiry
CLSS ?
Class Information inquiry 1
NOTE • The password used in PJLink
in the Web Control. To use PJLink
password in Web Browser Control.
• For specications of PJLink
Machine and Information System Industries Association.
URL: http://pjlink.jbmia.or.jp/ (as of Feb. 2012)
1st byte: Refers to Fan error; one of 0 to 2
2nd byte: Refers to Lamp error; one of 0 to 2
3rd byte: Refers to Temptrature error; one of 0 to 2
4th byte: Refers to Cover error; one of 0 to 2
5th byte: Refers to Filter error; one of 0 to 2
6th byte: Refers to Other error; one of 0 to 2
The mearning of 0 to 2 is as given below
0 = Error is not detected;
1 = Warning;
1st number (digits 1 to 5): Lamp Time
2nd number : 0 = Lamp off, 1 = Lamp on
11 12 21 22 23 31 33 41 51 52
Responds with the name set in the item
PROJECTOR NAME of the NETWORK menu
HITACHI
inquiry
CP-X8150
CP-X8160
CP-WX8240
CP-WX8255
CP-SX8350
CP-WU8440
CP-WU8450
Responds with the factory information and so
on
without authentication, do not set any
TM
, see the web site of the Japan Business
TM
PJLink command (continued)
Parameter or Response
2 = Error
is the same as the password set
TM
39