TECHNICAL DATA
MODELLO
TYPE
OUTPUT
(1)
FUEL
- Net calorific value
- Absolute density
- Max. delivery
- Pressure at maximum delivery
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATURE
COMBUSTION AIR TEMPERATUR
IN CONFORMITY TO EEC DIRECTIVES
APPROVAL
(1) Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m s.l.m.
(2) Pressure at test point 16)(A)p.10, with zero pressure in the combustion chambre, with open gas ring 2)(B)p.18 and maximum burner output
ELECTRICAL DATA
Motor IE1
MODELL
TYPE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
MOTOR CAPACITOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
Motor IE2
MODELL
TYPE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
COUNTRY
IT - AT - GR - DK - FI - SE
ES - GB - IE - PT
NL
FR
DE
BE
LU - PL
GAS 3 P/M
533 T1
2nd stage
kW
130 - 350
Mcal/h
112 - 301
1st stage
kW
80 - 175
Mcal/h
69 - 150
NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20
3
10
kWh/Nm
8.6
3
Mcal/Nm
0.71
3
kg/Nm
3
35
Nm
/h
mbar
11.1
(2)
• On - Off (1 stop min each 24 hours).
These burners are also fitted for the continuous operation.if they are equipped with
the control bow LANDIS type LGK 16.333 A27
(interchangeable with the burner control box Landis LFL 1.333)
• Progressive two-stage or modulating by kit (see ACCESSORIES)
Boilers: water. steam. diathermic oil
°C
°C max
2004/108 - 2006/95 - 2006/42
CE
GAS 3 P/M
533 T1
V
230 ~ +/- 10%
Hz
50 - single-phase
rpm
2750
kW
0.250
V
220 - 240
A
F
450/500
V
V1 - V2
I1 - I2
kW max
V
230 - 400 with neutral ~ +/- 10%
Hz
50 - threee-phase
rpm
kW
V
A
V1 - V2
I1 - I2
kW max
CATEGORY
II
2H3B / P
II
2H3P
II
2L3B / P
II
2ER3P
II
2ELL3B /P
I
I
2E(R)B,
3P
II
2E3B /P
GAS 4 P/M
534 T1
180 - 470
155 - 404
120 - 235
104 - 202
G25
G20
G25
8.6
10
8.6
7.4
8.6
7.4
0.78
0.71
0.78
41
47
54
16.4
9.8
14.5
GAS 4 P/M
534 T1
230 - 400 with neutral ~ +/- 10%
50 - threee-phase
2810
0.370
220 - 240
220/380-240/415
1.8
2.9
8
12.5
400/450
230 V - 1 x 8 kV
1.8 A - 30 mA
0.4
0.54
GAS 6 P/M
536 T1
2930
1.5
220/380
6.2 - 3.6
230 V - 1 x 8 kV
1.8 A - 30 mA
1.9
Important:
The installer is responsible for the addition of any
safety device not forseen in the present manual.
6
GAS 5 P/M
GAS 6 P/M
535 T1
536 T1
320 - 660
520 - 1050
275 - 568
447 - 903
155 - 330
300 - 520
133 - 284
258 - 447
G20
G25
G20
G25
10
8.6
10
8.6
8.6
7.4
8.6
7.4
0.71
0.78
0.71
0.78
66
77
105
122
9.8
14.5
12.3
18.2
0 - 40
60
0085AQ0707
GAS 5 P/M
GAS 6 P/M
535 T1
536 T1
2870
2840
0.750
1.5
220/380-240/415
2.85 - 1.65
6.4 - 3.7
0.85
2.0
IP 40
GAS 7 P/M
537 T1
2920
3.0
230/400
13.5 - 7.8
4.5
IP 40
GB
GAS 7 P/M
537 T1
800 - 1760
688 - 1514
400 - 880
344 - 757
G20
G25
10
8.6
8.6
7.4
0.71
0.78
176
205
14.5
21.4
GAS 7 P/M
537 T1
2840
3.0
220/380-240/415
11.6 - 6.7
3.7