Motor Cooling Fan Inspection And Cleaning; Seal Inspection; Separator Cleaning And Replacement (If Equipped); Vacuum Cleaner Disposal - Nilfisk ALKO ATTIX 140 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Motor cooling fan inspection and cleaning

Periodically clean the motor cooling fan to prevent the motor
from overheating, especially if the vacuum cleaner is used in
a dusty place.

Seal inspection

Figure 14
1
Hose
2
Hose
Hoses check
Make sure that connecting hose (1) is in a good condition
and correctly fixed.
If the hose is damaged, broken or badly connected to the
unions, it must be replaced.
When sticky materials are treated, check for possible
clogging along the hose (2), in the inlet and on the baffle
plate inside the filtering chamber.
Scrape the inlet from the outside and remove the
deposited waste as indicated in the figure.
Figure 15
1
Gasket
2
Screws
3
Filtering chamber
Filtering chamber tightness check
If the gasket (1) between the container and the filtering
chamber (3) fails to guarantee tightness:
Loosen the four screws (2) that lock the filtering
chamber (3) against the vacuum cleaner structure.
Allow the filtering chamber (3) to lower down and
tighten the screws once it has reached the tightness
position (2).
The gasket (1) must be replaced if it is torn, cut, etc...
Replace the gasket (1) if the degree of tightness is still
not optimum.
Separator cleaning and replacement (if
equipped)
Figure 16
1
Separator
2
Lever
3
Cover
4
Screws
[ NOTE ]
If there is only a dust deposit on the separator (1) allow
the dust to drop through the central hole.
The separator (1) should first be disassembled in order to be
perfectly cleaned:
Use the lever (2) to remove the lid (3) together with the
filter.
Unscrew the two screws (4) and remove it from the
container.
Replace the part if it is excessively worn. Assemble the
components in the reverse order of disassembly.
11/2008

Vacuum cleaner disposal

Dispose of the vacuum cleaner in compliance with the laws in
force.
-
Proper disposal (electric and electronic waste) (applicable
in the European Union and in countries providing a
separate collection system)
The above symbol, which is present on the product or o in its
documentation, indicates that the product can not be disposed
of together with other domestic waste at the end of its cycle of
life.
To prevent damages to the environment or the health caused
by improper waste disposal, please separate this product from
other waste and recycle it responsibly in order to support the
sustainable reuse of material resources. Domestic users should
contact the retailer or the local office providing information on
separate collection and recycling of this product.
Companies should contact the supplier and check the purchase
contract terms and conditions.
This product can not be disposed of together with other commercial
waste.

Wiring diagrams

Basic vacuum cleaner
1
Plug
2
Vacuum cleaner
3
Circuit breaker
Name
Part
Circuit breaker
Q1
Box for Q1
Wet vacuuming kit
1
Power supply
2
Transformer
3
Liquid sensor
4
Auto release
5
Vacuum cleaner
6
Circuit breaker
Name
Part
Circuit breaker
Q1
Handle for Q1
B1
Auto release
PR1
Pressure switch
F1 - F2
Fuse holder
TR1
Transformer
9
ATTIX 140 - ATTIX 150
Figure 17
Figure 18
Code
ATTIX 140
ATTIX 150
8 391156
8 391157
8 391052
8 391052
Figure 19
Code
ATTIX 140
ATTIX 150
8 39915
8 39916
8 39954
8 39954
8 391142
8 391142
8 40841
8 40841
8 39244
8 39244
8 391050
8 391050
GB
C320

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Alko attix 150

Table des Matières