Kompressor helps in preventing from moisture damage where books or valuables are stored, in
basements, etc. its built-in drain pump allows to drain condensates to a maximum height of
5 meters. in terms of hygiene and comfort, Air Naturel advices a relative humidity between
40 and 60%.
Starting the Kompressor
Before plugging the device on mains
power, check that the Kompressor is turned off.
if the unit was transported lying down, place
it in a vertical position and let it stand 3 hours
to let the refrigerant stabilizes. When first using
the dehumidifier, operate the unit continuously
for 24 hours.

CoNTroL PANeL

Auto defrost
PUMP
HYGRO
FILTER
CONTINUE TURBO
SMART
©
① Pump pad
Press to activate the pump operation.
CAUTioN : Make sure the pump drain hose
is installed into the unit and the continuous
drain hose is removed from the unit before
the pump operation is activated.
② HygroSmart
function pad
®
Press
to
activate
the
HygroSmart
dehumidifying operation. CAUTioN: on
this operation,the unit can not be set
humidity level.
③ Filter Pad
The check filter feature is a reminder
to clean the Air Filter for more efficient
operation. The Filter light(Clean filter light)
will illuminate after 250 hours of operation.
To reset after cleaning the filter, press the
Filter pad and the light will go off.
④ Continue mode pad
Press
to
activate
the
continuous
dehumidifying operation.
⑤ Turbo mode pad
Control the fan speed. Press to select
either High or Normal fan speed.
12
Place the humidifier on the floor.
Plug the power cord to the mains power
and turn the device on.
Check whether the filter is in place. Never
use the device without filter.
The Dehumax dehumidifier is now ready
to use☺.
Full
On
Off
TIMER
POWER
⑥ Timer pad
Press to initiate the Auto start and Auto
stop feature, in conjunction with the
⑦ key pads.
⑦ up/Down pads (
)
Humidity Set Control Pads:
For drier air, press the
pad and set to a
lower percent value (5% increments). For
®
damper air, press the
pad and set a
higher percent value (5% increments).
Timer set control pads:
Use the
⑦ pads and set a higher
percent value.
⑧ Power pad
Press to turn the dehumidifier on and off.
⑨ LCD screen
The screen shows the actual room humidity
level then it shows the set humidity level
while setting the unit.
CAUTioN, the following error codes Can
be displayed :
- AS: humidity sensor error. Unplug the unit
and plug it back in. if error repeats, call
for service.
- eS: Tube Temperature sensor of the
evaporator error. Unplug the unit and plug
it back in. if error repeats, call for service.
- P2: Water tank is full. Empty the water
tank.
- ec: Refrigerant leakage detection. With
this new technology, the display area
will appear ec when the unit detects
refrigerant leakage ,call for service.
- e3: Unit malfunction. Unplug the unit and
plug it back in. if error repeats, call for
service.
HoW To uSe
Press "Power" ⑧ to turn on and off the
unit. The screen ⑨ illuminates when
Kompressor is on.
The humidity level can be set with
pads and the digital display ⑨.
Press the accurate pad in order to initiate
the desired function of Kompressor (see
"Control panel" and "Function" sections).

FuNCTIoNS

How to use the different functions of
Kompressor.
Auto Shut off ⑪
The unit shuts off when the bucket is full, or
when the bucket is removed or not replaced
in the proper position. When the setting
humidity is reached, the unit will be shut off
automatically.
Continuous mode ④
Continuous
operation
allows
maximum
dehumidification.
The
unit
dehumidifies
continuously, without taking into account the
relative humidity of the ambient air. CAUTioN:
on this mode, the
⑦ pads can not be
operated.
HygroSmart
mode
©
HygroSmart
function allows maximum comfort
©
for the user. When this function is engaged,
the unit will automatically control the relative
humidity on a comfortable range between
45% ~ 55%, depending on the ambient
temperature. CAUTioN: on this monde, the
⑦ pads can not be operated.
- eb: Water tank is removed or not in right
position. Replace it bucket in the right
position.
⑩ Water tank full indicator light
The indicator lights to indicate that the tank
is full.
⑪ Auto defrost operation on indicator light
The indicator lights to indicate that auto
defrost operation is on.
once
the
function
is
activated,
concerned light indicator lights.
Press the button again to exit the selected
mode. When the tank is full or when it has not
been placed correctly, the LED "Full" ⑩ lights
and Kompressor stops.
Turbo mode ⑤
Turbo operation allows to control the fan
speed for more efficiency. Set the fan control
to High for maximum moisture removal.
CAUTioN: When the humidity has been
reduced and quiet operation is preferred, set
the fan speed to normal.
Timer ⑥
Kompressor features an Auto Start and Auto
Stop function within a range of 0 to 24h
(increments of 0,5h between 0 and 10h ;
increments of 1h between 10 and 24h).
Case 1 : the unit is switched off
initialize Auto Start:
Press the timer button ⑥ (the "timer on"
indicator light illuminates) and use
pads to settle the Auto Start.
initialize Auto Stop:
Press the timer button ⑥ two times (the "timer
off" indicator light illuminates) and use
pads to settle the Auto Stop.
Case 2 : the unit is switched on
initialize Auto Stop:
Press the timer button ⑥ (the "timer off"
the
13

Publicité

Table des Matières
loading

Table des Matières