Manual For Display Controller; Auto Programming - ThermoTec AeroFlow Mode D'emploi

Masquer les pouces Voir aussi pour AeroFlow:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Manual for display controller

1. View in operating mode OFF
When the device is in the OFF operating
mode, the following symbol
the display.
2. Setting the time
Press the
button in the operating mode
OFF.
The date display flashes.
Select the desired day with + or – button.
Confirm with OK, then set the hour and
after that the minutes. To exit the setting
mode press the ON-OFF key.
Notice:
1 = Monday
5 = Friday
2 = Tuesday
6 = Saturday
3 = Wednesday
7 = Sunday
4 = Thursday
3. First commissioning
During inital operation the COMFORT pro-
gram is used every day from 8:00 am until
10:00 pm and NIGHT REDUCTION from
10:00 pm until 8:00 am.
The ON symbol in the display indicates that
the device is heating.
By pressing the i button you can display the
room temperature or the set temperature.
(You can define the following settings in the
configuration menu 6.4.)
4. Operation and selection of the operating mode
The operating mode button is not activated until the device has been switched
on using the On-Off button.
The various modes are selected with the
MODE button.
COMFORT
NIGHT
FROST PROTECTION
AUTO with programming
AUTO
Note – alignment of the temperature sensor
The temperature sensor is attached to the bottom of the radiator in a clip. If, due
to an placement of the device in a niche or corner, the room temperature and
the measured temperature is influenced, it can be removed from it. The distance
to the radiator can be increased by turning the connection cable of the sensor.
Alternatively, the settings of menu item 2 can be performed.
appears in
PROG
On-Off
-
+
On-Off
-
+
On-Off
On-Off
4.1 Explanation of operating modes
4.1.1 Comfort permanent mode
The device permanently ensures the set tempe-
rature.
The temperature can be adjusted by pressing the
+ or – button in steps of 0.5°C (from + 5 to + 30°C).
4.1.2 Nighttime lowering permanent operation
Mode
The desired lowering can be regulated in the con-
figuration menu 1. The device permanently ensu-
res the adjusted temperature.
1
The temperature can be adjusted by pressing the
2
3
+ or – button in steps of 0.5°C (from + 5 to + 30°C).
4
5
6
7
If you can't change this value, set configuration
menu 1 to "----": Refer to 6.1 in this manual.
OK
4.1.3 Permanent frost protection
The device permanently ensures the set tempe-
rature in this mode.
Mode
The temperature can be adjusted by pressing
the + or – button in steps of 0.5°C (from + 5 to +
15°C).
ON

4.1.4 AUTO Programming

In this operating mode, the device is automatically
i
controlled according to the set programming. The
current hour with its comfort, night-time lowering
or frost protection setting flashes in the display.
Mode
5. Setting display change AUTO programming
Mode
Two bars =
„Comfort"
One bar =
„Nighttime lowering"
Press for
1 hour „Comfort"
Oh 2
4
6
PROG
1
PROG
2
3
4
5
6
7
Oh 2
4
6
8 10 12 14 16 18 20 22 24
OK
Press for
1 hour „Frost protection"
Press for
1 hour „Nighttime lowering"
-
+
i
-
+
i
-
+
i
1
AUTO
2
3
4
5
6
7
8 10 12 14 16 18 20 22 24
i
Day
No bar =
„Frost protection"
Confirmation
and Continue to
change / setting
of the next day