Manual for display controller
6. Configuration menu
You can define the following settings in the
configuration menu:
- Regulate the setting value for nighttime
lowering
- Correction of the measured temperature
- Duration of the background lighting
- Selection of the temperature display in the
AUTO mode
- de-/active window open detection
- de-/active adaptive start control
- Call up the product number
Call up the configuration menu
In the OFF mode you open the first confi-
guration menu by pressing the On-Off-switch
for 10 seconds.
Menu 1
6.1 Regulate the setting value for nighttime
lowering
Default value Nighttime lowering = Tempe-
rature value of COMFORT minus 3.5°C. This
lowering can be changed in graduations of
0.5°C from 0 to 10°C. Change with the button
+ or –. Confirm with the OK button.
Press the button + until "----" appears in the
display to authorise the change of the value
by the user.
Refer to 4.1.2 Nighttime lowering perma-
nent operation
Menu 2
6.2 Correction of the measured temperature
If the room temperature deviates from the
temperature measured on the radiator (
displayed on the device), use Menu 2. A
compensation value for the measuring sensor
from - 5°C to + 5°C can be entered here (in
steps of 0.1°C).
Example: • room temperature = 21°C
• measured temp. = 20°C
• Set +1,0°C in Menu 2.
Change with the button + or –. Following this
confirm with the OK button.
Menu 3
6.3 Duration of the background lighting
The duration of the lighting can be set in
steops of 15 seconds between 0 and 225 se-
conds.
The default value is 90 seconds.
Change with the button + or –.Following this
confirm with the OK button.
PROG
On-Off
Mode
menu number
1
2
3
4
5
6
7
-
+
OK
1
2
3
4
5
6
7
-
+
OK
1
2
3
4
5
6
7
OK
-
+
1
2
3
4
5
6
7
-
+
OK
Menu 4
6.4 Selection of the temperature display in
the AUTO mode (programming)
0 = permanent display of the room tempera
ture.
1 = permanent display of the set tempera-
ture.
Change with the button + or –. Following this
confirm with the OK button.
Menu 5
6.5 Open Window detection
The detection of an open window occurs
when the room temperature falls rapidly.
In this case, the display shows a flashing
pictogram, as well as the frost protection
set-point temperature.
0 = Open window detection is deactivated
1 = Open window detection is activated
Change with the button + or –. Following this
confirm with the OK button.
If a open window is detected (
can deactivate this function temporarily by
pressing
.
When the window is closed again, it may take
a few minutes for the radiator to continue
heating.
Please note: an open window cannot be
detected in OFF-Mode.
Menu 6
6.6 Adaptive start control
This feature enables to reach the set-point
temperature at a set time.
When this feature is activated, the display
shows a flashing
.
0 = Adaptive start control deactivated
1 = Adaptive start control activated
Change with the button + or –. Following this
confirm with the OK button.
Adjusting the time-temperature-slope
(when adaptive start control is activated)
From 1°C to 6°C, in steps of 0.5°C.
If the set-point temperature is reached too
early, then a lower value should be set.
If the set-point temperature is reached too
late, then a higher value should be set.
Menu exit
6.7 Product number
The product number can be displayed with
this menu. To exit the configuration mode
press the OK key.
-
-