Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Remove the lower spray arm.
Remove the filter group (C). Press the lips
together slightly and unscrew the filter
group by turning it to the left
(anticlockwise) (1).
Take out the filter assembly by pulling it
vertically upwards (2) (see fig. 16a).
Remove the microfilter (D). Push it out of
the housing from underneath (see fig. 16b).
Remove the filter (F). Pull the filter out of
the filter housing vertically (see fig. 16c).
Remove the large filter (G) (see fig. 16d).
Clean filters F and G under running water
with a brush.
Reassemble the filter mesh and filter in
reverse order.

Installation

Electrical connection
230 V – 50 Hz
General
If the appliance does not have a connecting
G
cable and plug, then it may only be connected
to the mains by an approved installer.
Note:
The power rating and required mains voltage
fig. 16d
are shown on the rating plate. Connection
should take place according to national and
local regulations.
If the input of the appliance exceeds 3 kW, the
appliance has to be connected to an outlet
with a rated current exceeding 13 Amps.
Technical information
Connected load
Dimensions:
Max. height
Min. height
Width
Depth
Door panel:
Max. height
Min. height
Depth
Plinth:
Max. height
Min. height
kW
see identification
plate
mm
870
mm
820
mm
596
mm
550
mm
720
mm
650
mm
598
mm
170
mm
100

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gvw865

Table des Matières