TROUBLE-SHOOTING
Fault condition 3
Crimping is completed. Cable cannot be pulled out.
Disconnect the mains supply from the
mc 25 and open cover.
1. Stop operation
 Read counter (1) if required.
 Press the reverse button (2) to move the mc 25
into start position.
 Turn off (position 0) the mc 25 with mains
switch (3).
 Disconnect mains cable (4).
2. Remove the tool insert
 Slide back the cover (1).
 Pull out the bolt (2).
 Press lower stripping cutter (3) upwards and
remove the tool insert (4) sideways.
If it is impossible to remove the tool
!
insert then carry out step 4, else carry
on with step 3.
 Remove end sleeve (5).
 Bend cable aside (6)
10/12
Diagram 23
Stop operation
Diagram 24
Remove the tool insert
19