7 MAINTENANCE
7.1   Cleaning
 
 
CAUTION:   Disconnect  the  Ranger  Count  1000 Scale
supply  before  cleaning.  
 
The  housing  may  be  cleaned  with  a cloth  dampened  with  a mild  detergent  if  
necessary.   
 
Attention:   Do  not  use  solvents,  chemicals,  alcohol,  ammonia  or  abrasives  to  
clean  the  housing  or  control  panel.   Do  not  allow  liquids  to  enter  the  housing.  
7.2 Troubleshooting
The following table lists common problems, possible causes and remedies. If the
problem persists, contact Ohaus or your authorized Ohaus dealer.
Symptom
Scale will not turn on.
Battery fails to charge fully.
Weight reading does
not stabilize.
Scale does not display
accurately.
E1, E2, E3 displayed
--OL-- displayed
 
 
7.3   Service
 
If  the  troubleshooting
contact  your  authorized  OHAUS  service  agent.  For  service  assistance  or  
technical  support  in  the  United  States  call  toll -free  1-800-526-0659 between
8:00 AM  and  5:00 PM  EST.  An  OHAUS  product  service  specialist  will  be  
available  to  provide  assistance.  Outside  the  USA,  please  visit  our  web  site,  
www.ohaus.com  to  locate  the  OHAUS  office  nearest  you.  
Possible Causes
AC power not connected.
Battery discharged.
Battery is defective or past its
useful life.
Unstable environment.
Interference under pan.
Improper calibration.
The pan is placed incorrectly.
Zero limit exceeded during
power up.
Load exceeds scale capacity.
Information
 
 section  does  not  resolve  or  describe  your  problem,  
 
from the
 
Remedy
Connect scale to power.
Connect scale to power and
charge battery.
Have the battery replaced by an
authorized Ohaus service dealer.
Ensure a stable environment.
Ensure that the weighing pan is
unobstructed and free to move.
Calibrate the scale using proper
calibration weights.
Reposition the pan correctly.
Ensure the pan is empty before
switching the scale on.
Reduce the load on the pan.