to the eff ects of animal hooves or tractor wheels sinking into the ground.
• Connec ng leads shall not be installed in the same conduit as the mains supply wiring, communica on
cables or data cables.
• Connec ng leads and electric animal fence wires shall not cross above overhead power or communica on
lines.
• Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot be
avoided it shall be made underneath the power line and as nearly as possible at right angles to it.
• If connec ng leads and electric animal fence wires are installed near an overhead power line, the clearances shall not be
less than those shown in the table below.
Minimum clearances from power lines for electric animal fences
Less than or equal to 1 000
Greater than 1 000 and less than or equal to 33 000
Greater than 33 000
• If connec ng leads and electric animal fence wires are installed near an overhead power line, their height
above the ground shall not exceed 3 m
This height applies either side of the orthogonal projec on of the outermost conductors of the power line
on the ground surface, for a distance of:
2 m for power lines opera ng at a nominal voltage not exceeding 1 000 V;
-
15 m for power lines opera ng at a nominal voltage exceeding 1 000 V.
-
• Electric animal fences intended for deterring birds, household pet containment or training animals such as
cows need only be supplied from low output energizers to obtain sa sfactory and safe performance.
• In electric animal fences intended for deterring birds from roos ng on buildings, no electric fence wire shall
be connected to an earth stake. A warning sign shall be fi ed to every point where persons may gain ready
access to the conductors.
• Fence wiring should be installed well away from any telephone or telegraph line or radio aerial.
• Where an electric animal fence crosses a public pathway, a non-electrifi ed gate shall be incorporated in the
electric animal fence at that point or a crossing by means of s les shall be provided. At any such crossing, the
adjacent electrifi ed wires shall carry warning signs.
• Any part of an electric animal fence that is installed along a public road or pathway shall be iden fi ed by
electric fence warning signs (G6020) at regular intervals that are securely fastened to the fence posts or
fi rmly clamped to the fence wires.
• The size of the warning sign shall be at least 100mm x 200mm.
• The background colour of both sides of the warning sign shall be yellow. The
inscrip on on the sign shall be black and shall be either:
- the substance of "CAUTION: Electric Fence" or,
4
Power line Voltage V
Gallagher 3E3958 110V Energizer User Manual
Clearance m
3
4
8