7. Requirement on local design

• This interface is to connect Mr. Slim inverter outdoor unit of MITSUBISHI ELECTRIC to local applications. Please check the following when designing the local system.
• MITSUBISHI ELECTRIC does not take any responsibility on the local system design. Therefore, MITSUBISHI ELECTRIC does NOT take any responsibility on the failure
(including outdoor unit) caused by local AHU and system design. Also R32 is flammable refrigerant, and the fire safety warranty for the whole system (including outdoor
unit) must be done by your side when using R32 refrigerant.
• Conformity of regulations and laws must be confirmed on the system by your side.
• See the document "AIR-HANDLING UNIT (AHU) DESIGN GUIDELINE" for more information. To get it, contact your dealer.
7.1. Air flow volume
Standard air flow volume
Model capacity of outdoor unit
Maximum air volume
Minimum air volume
Make sure to keep the air flow volume within the limits of maximum and minimum below.
(1) Maximum air volume
Number of
Step mode
outdoor unit
Manual
2-6
1
Auto
2-5
1
*1. 600% of selected outdoor unit's maximum standard air volume is available ONLY when 6 same capacity outdoor units are connected.
*2. 528% of selected outdoor unit's maximum standard air volume is available ONLY when 6 same capacity outdoor units are connected.
Note:
• When multiple outdoor units are connected, basically select one interlaced heat exchanger which has multiple refrigerant circuit or multiple heat exchanger placed
in parallel to the air flow. If multiple heat exchangers placed in series with the air flow have to be used, maximum 2 heat exchanger in series are acceptable.
(2) Minimum air volume
Total amount of selected outdoor unit's minimum standard air volume is allowable.
7.2. Indoor heat exchanger
(1) Indoor heat exchanger volume
Make sure to keep the HEX capacity within the following range.
If the piping length is 30m or shorter, HEX capacity can be increased as follows.
Model capacity of outdoor unit
Max. volume [cm
]
3
Pipe length
Min. volume
[cm
]
3
Note: Calculate them by linear interpolation in case of other piping lengths not shown on this table.
(2) Diameter of header
With a bigger size header, the refrigerant flow velocity decreases and this disturbs the sufficient circulation of refrigerant oil. As a result, the refrigerant oil does not
flow properly and could cause a serious damege of compressor.
Use the pipe whose outside diameter is less than the value shown in the table below.
Model capacity of outdoor unit
Max. diameter of header [mm]
Model capacity of outdoor unit
Max. diameter of header [mm]
ZRP
35
50
P
SHW
ZM
35
50
[m³/min]
12.3
18
[m³/h]
738
1080
[m³/min]
6.2
8.6
[m³/h]
372
516
Capacities of the
connected outdoor units
[For PUHZ-ZRP, P, SHW models] 500% of selected outdoor unit's maximum standard air volume *1
The same
[For PUZ-ZM models] 440% of selected outdoor unit's maximum standard air volume *2
Different
[For PUHZ-ZRP, P, SHW models] If smaller capacity outdoor unit's rated heating capacity is under 20% of total
heating capacity, 500% of bigger capacity outdoor unit's maximum standard air volume is allowable.
If smaller capacity outdoor unit's rated heating capacity is 20% or more of total heating capacity, 500% of smaller
capacity outdoor unit's maximum standard air volume is allowable.
[For PUZ-ZM models] If smaller capacity outdoor unit's rated heating capacity is under 20% of total heating
capacity, 440% of bigger capacity outdoor unit's maximum standard air volume is allowable.
If smaller capacity outdoor unit's rated heating capacity is 20% or more of total heating capacity, 440% of smaller
capacity outdoor unit's maximum standard air volume is allowable.
200% of selected outdoor unit's maximum standard air volume
[For PUHZ-ZRP, P, SHW models] 500% of the smallest capacity outdoor unit's maximum standard air volume
[For PUZ-ZM models] 440% of the smallest capacity outdoor unit's maximum standard air volume
200% of selected outdoor unit's maximum standard air volume
ZRP
35
50
P
SHW
ZM
35
50
30m -
1050
1500
20m
1350
1800
10m
1650
2100
350
500
ZRP
35
50
P
SHW
ZM
35
50
60
71
100
80
112
60
71
100
21
24
33.6
1260
1440
2016
10.5
12.2
16.3
630
732
978
Maximum air volume
60
71
100
80
112
60
71
100
1800
2130
3000
2700
3030
3900
3600
3930
4800
600
710
1000
60
71
100
80
112
{19
60
71
100
{14
125
140
200
200
140
230
125
140
42
48
67.2
2520
2880
4032
21.5
23.0
32.6
1290
1380
1956
125
140
200
200
140
230
125
140
3750
4200
6000
4650
5100
7800
5550
6000
9600
1250
1400
2000
125
140
200
200
140
230
{28
125
140
{21
250
250
81
4860
37.8
2268
250
250
7500
9300
11100
2500
250
250
21