STORAGE
Before you store the air compressor, make
sure you do the following:
1. Review the Maintenance section on the
preceding pages and perform scheduled
maintenance as necessary.
2. Set the On/Off switch (1) to OFF and
unplug unit.
3. Turn the regulator (6) counterclockwise
and set the outlet pressure to zero.
4. Remove the air tool or accessory.
5. Pull ring on safety valve (3) allowing air to
bleed from the tank until tank pressure is
approximately 20 psi (1,4 bar). Release
safety valve ring.
6. Drain water from air tank by opening
drain valve (8) on bottom of tank.
WARNING. Risk of Bursting. Water will
condense in the air tank. If not drained,
water will corrode and weaken the air tank
causing a risk of air tank rupture.
7. After the water has been drained, close
drain valve (8) by turning clockwise.
NOTE: If drain valve is plugged, release all air
pressure. The valve can then be removed,
cleaned, then reinstalled.
8. Protect the electrical cord and air hose
from damage (such as being stepped on
or run over).
9. Store the air compressor in a clean and
dry location.