MAINTENANCE

Customer Responsibilities

Check Safety Valve
Drain Tank
WARNING. Unit cycles automatically
when power is on. When performing main-
tenance, you may be exposed to voltage
sources, compressed air, or moving parts.
Personal injuries can occur. Before per-
forming any maintenance or repair, discon-
nect power source from the compressor
and bleed off all air pressure.
NOTE: See Operation section for the location
of controls.
To Check Safety Valve
WARNING.If the safety valve does not
work properly, over-pressurization may
occur, causing air tank rupture or an
explosion.
Before starting compressor, pull the ring on
the safety valve (3) to make sure that the
safety valve operates freely. If the valve is
stuck or does not operate smoothly, it must
be replaced with the same type of valve.
To Drain Tank
WARNING.Risk of Unsafe Operation. Air
tanks contain high pressure air. Keep face
and other body parts away from outlet of
drain. Use safety glasses when draining as
debris can be kicked up into face. Risk from
noise. Use ear protection (ANSI S12.6 (S3.19)
hearing protection) as air fl ow noise is loud
when draining.
GB
28
Before
Daily
or after
each
each
use
use
NOTE: All compressed air systems generate
condensate that accumulates in any drain
point (e.g., tanks, fi lter, aftercoolers, dry-
ers). This condensate contains lubricating oil
and/or substances which may be regulated
and must be disposed of in accordance with
local, state, and federal laws and regulations
1. Set the On/Off switch (1) to OFF.
2. Turn the regulator knob (6) counter-clock-
wise to set the outlet pressure to zero.
3. Remove the air tool or accessory.
4. Pull ring on safety valve (3) allowing air to
bleed from the tank until tank pressure is
approximately 20 psi (1,4 bar). Release
safety valve ring.
5. Drain water from air tank by opening
drain valve (8) on bottom of tank.
WARNING. Risk of Bursting. Water will
condense in the air tank. If not drained,
water will corrode and weaken the air tank
causing a risk of air tank rupture.
CAUTION. Risk of Property Damage.
Drain water from air tank may contain oil
and rust which can cause stains.
6. After the water has been drained, close
the drain valve (8). The air compressor
can now be stored.
NOTE: If drain valve is plugged, release all
air pressure. The valve can then be removed,
cleaned, the reinstalled.