Know Your Product - Rona RCK2-4 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

KNOW YOUR PRODUCT

Know your product
1. On(I)/Off(O) Switch: Place this switch in
the ON (I) position to provide automatic
power to the pressure switch and OFF (O)
to remove power at the end of each use.
2. Pressure Switch (not shown): The pres-
sure switch automatically starts the motor
when the air tank pressure drops below the
factory set "cut-in" pressure. It stops the
motor when the air tank pressure reaches
the factory set "cut-out" pressure.
3. Safety Valve: If the pressure switch does
not shut off the air compressor at its "cut-
out" pressure setting, the safety valve will
protect against high pressure by "popping
out" at its factory set pressure (slightly
higher than the pressure switch "cut-out"
setting).
4. Outlet Pressure Gauge: The outlet pres-
sure gauge indicates the air pressure avail-
able at the outlet side of the regulator. This
pressure is controlled by the regulator and
is always less than or equal
to the tank pressure.
5. Tank Pressure Gauge:
The tank pressure gauge
indicates the reserve air
pressure in the tank.
6. Regulator: Controls the air
pressure shown on the outlet
pressure gauge. Pull the
knob out and turn clock-
wise to increase pressure
and counterclockwise to
decrease pressure. When
the desired pressure is
reached push knob in to lock
in place.
7. Universal Quick-Connect
Body: The universal quick-
connect body accepts the
three most popular styles of
quick-connect plugs: Indus-
trial, automotive, and ARO.
One hand push-to-connect
operation makes connec-
GB
tions simple and easy.
18
8. Drain Valve: The drain valve is located at
the base of the air tank and is used to drain
condensation at the end of each use.
9. Cooling System (not shown): This
compressor contains an advanced design
cooling system. At the heart of this cooling
system is an engineered fan. It is perfectly
normal for this fan to blow air through the
vent holes in large amounts. You know that
the cooling system is working when air is
being expelled.
10. Air Compressor Pump (not shown):
Compresses air into the air tank. Working
air is not available until the compressor
has raised the air tank pressure above that
required at the air outlet.
11. Check Valve: When the air compressor is
operating, the check valve is "open", al-
lowing compressed air to enter the air tank.
When the air compressor reaches "cut-out"
pressure, the check valve "closes", allowing
air pressure to remain inside the air tank.
11
8
3
4
1
7
6
5

Publicité

Table des Matières
loading

Table des Matières