3.3 Product description

Ceiling fan for air circulation in commercial
and working areas.
EC 30 E and EC 40 D run clockwise.
EC 90 B and EC 140 B run anti-clockwise
(see direction of rotation arrow sign [S5]).
The motor is designed for continuous
operation. In the event of thermal overload,
an integrated motor overload switches the
unit off.
They are switched on and off using a
separate switch (this should be supplied by
the customer). The unit is speed controllable,
see recommended Maico accessories.

4. Technical data

Protective cage diameter
EC 30 E
EC 40 D
Impeller diameter
EC 90 B
EC 140 B
Mount ing height
EC 30 E
EC 40 D
EC 90 B
EC 140 B
W eight
EC 30 E
EC 40 D
EC 90 B
EC 140 B
Air circulation (max.)
EC 30 E
EC 40 D
EC 90 B
EC 140 B
Permissible ambient temperature
EC 30 E, EC 40 D
EC 90 B, EC 140 B
For other data, see rating plate.

5. Essential safety instructions

5.1 General safety instructions

345 mm
450 mm
900 mm
1400 mm
410 mm
420 mm
450 mm
420 mm
2.5 kg
3.2 kg
5.1 kg
8.5 kg
2,800 m³/h
4,500 m³/h

5.2 Intended use

11,000 m³/h
18,000 m³/h
max. + 40 °C
max. + 60 °C
Read the operating instructions through
carefully before starting up.
Keep the instructions.
The unit should not be used as a toy.
Installation is only permitted when
carried out by trained specialists.
Electrical connection, repairs and
conversion to a longer fastening rod
(accessories) should only be carried
out by a trained electrician.
Only connect unit to a permanently wired
electrical installation.
– Permissible cable cross-section
1.5...2.5 mm².
– Mains isolation device required with
contact openings of at least 3 mm at each
pole.
The fan unit may only be operated using
the voltage and frequency shown on the
rating plate.
Only operate the fan unit when it is
completely installed.
Never operate EC 30 E and EC 40 D
without protective cage.
Modifications and alterations to the unit are
not permitted and release Maico from any
guarantee obligations and liability.
Exception: the unit may be modified to a
longer fastening rod (Maico accessories)
according to section 8.
Ceiling fan for constant air circulation in
rooms with high ceilings, commercial and
industrial halls, offices, production and
operating facilities. Air circulation produces
an even distribution of temperature in the
room.
The air flows from the ceiling to the floor.
For surface installation on a ceiling with
sufficient load bearing capacity.