ENGLISH___________________________________________________________________
IMPORTANT: The instruction manual you are holding includes essential information on the safety measures to be implemented for
installation and start-up. Therefore, the installer as well as the user must read the instructions before beginning installation and start-up.
Keep this manual for future reference.
Disposal of waste electrical and electronic domestic systems in the European Union.
All the products marked with this symbol indicate that the product shall not be mixed or disposed with your
household waste at their end of use. It is responsibility of the user to eliminate this kind of wastes depositing them in
a recycling point adapted for the selective disposal of electrical and electronic wastes. The suitable recycling and
treatment of these wastes contributes in essential way to the preservation of the Environment and the health of the
users. For further information regarding the points of collection of this type of wastes, please contact to the dealer
where you acquired the product or to your municipal authority.
For optimum performance of the Astralpool Chlore Salt Electrolysis System, we recommend you to follow the instructions given below:
1. CHECK THE CONTENTS OF THE PACK:_____________________________________________________________________________
You should find the following elements inside the box
Power supply
Electrolysis cell
Operation Manual
2. GENERAL FEATURES:___________________________________________________________________________________________
When Astralpool Chlore Salt Electrolysis System is installed, a quantity of salt is dissolved into the swimming pool water. This salty water
then passes through the electrolysis cell that is located in the plant room. The Astralpool Chlore Salt Electrolysis System consists of two
elements: an electrolysis cell and a power supply. The electrolysis cell contains a quantity of titanium plates (electrodes).
When a weak electrical current is passed through the plates inside the electrolysis cell, chlorine is produced. Maintaining a level of chlorine
in swimming pool water keeps the water sanitised and healthy to swim in. The Astralpool Chlore Salt electrolysis System will manufacture
chlorine whenever the pool circulation system (pump and filter) is operational.
The power supply is provided with various safety devices, which are activated in case of irregular operation of the system, as well as a
microprocessor driven control system.
The Astralpool Chlore Salt electrolysis Systems has an automatic cleaning system that avoids scale formation on the electrodes.
DESCRIPCION
Standard working voltage
Output (dc)
Production (g/h)
Flow detector
Salinity range / Temperature
Electrodes
Production control
Cover control
Polarity switch
Voltage
Salt level protection
(1)
Factory defaults
SMART 30 – Code 42347
6 A
5 - 6
Estimated lifetime:3.000 – 5.000 hours of operation (depending on water quality)
Programmable reduction of production to 10% of its nominal value from control panel when closed cover
Programmable 2
Input for potential free contact enabled by jumper in control board
Logics: ON (closed contact) / OFF (open contact)
1
MODEL
SMART 60 – Code 42348
230 V AC, 50/60 Hz.
12 A
10 -12
Gas detector
o
o
o
4 – 6 g./l. / 15
C – 40
C (59
F - 104
SELF-CLEANING coated Titanium
0 – 100 % (5 production levels)
Input for potential free contact
(1)
/ 3 hours + test mode (jumper in control board)
Automatic protection of output current
SMART 100 – Code 42349
24 A
20 -24
o
F)