BL- and BL+: This is for connecting the name tag lighting. Only LEDs
can be connected; make sure that the polarity is correct.
For the connected LEDs to light up, the brightness sensor must be
connected and shaded over.
Output: 12 V DC max. 60 mA
Bottom connection terminal (24-pole)
This terminal is for connecting the individual apartments. Up to four
internal units can be connected in parallel for each apartment. VIDEO1,
GND, +15V and AUDIO1 for apartment 1, etc.
Left connection terminal (4-pole)
LOCK- and LOCK+: This is for connecting the door opener. Some door
openers have a flyback diode fitted. If this is the case, make sure that
the polarity is correct. If the door opener only responds for a short
time (less than one second), its current consumption is too high. The
door opener should then be replaced with a model which uses less
current (maximum of 0.9 A). Alternatively a relay can be connected up
between the door opener and the terminal.
+15V and GND: This is for connecting the operating voltage.
You do not need to do this if you are using the recommended
star wiring.
Right connection terminal (4-pole)
This is for connecting an additional camera. Do not use the X module
with the VDV-500 Xcam, if the latter is used. The best thing is to cut the
cable to the camera just behind the X module. Then strip the insulation
from the cable. The three wires thus exposed are hooked up to the
connection: red to VCC, black to GND and yellow to Video. If you want
to use a camera from a different manufacturer, this must comply with
the following technical data:
12 V operating voltage, max. 500 mA current consumption, FBAS video
signal (1 Vpp, 75 ohm)
VCC is connected to the positive pole of the camera's power connection.
GND is connected to the negative pole of the camera's power
connection.
VIDEO is connected to the video output of the camera. On most
cameras, the negative pole is connected directly to the video ground. In
a few rare cases, the video ground also has to be connected to GND.
Please note that the camera is only supplied with power at this connec-
tion when the external camera is activated at the internal unit.
VDV-B90+40_I-Manual_210x240_Fin3.indd 11
FITTING RECOMMENDATIONS
During fitting, the power supply should be switched off
to avoid short circuits.
The tech box must be attached in such a manner that rain water cannot
penetrate it.
The connection cables of the camera, loudspeaker and microphone
modules, as well as the brightness sensor, should not be extended. They
may however be shortened.
A 3 mm diameter hole is needed for the brightness sensor. The sensor
should be able to be retained in the hole of its own accord; if necessary
you can use hot glue or with an adhesive pad to fix it in position.
Adhesive pads designed especially for the camera, loudspeaker and
microphone modules, respectively, are included. You can use these to
secure those items at their desired locations. If you want to attach the
modules with screws, you should use the relevant module as template.
The loudspeaker and microphone modules should not be fitted directly
next to one another. This is to prevent feedback.
A hole with a diameter of 52 mm is needed for the camera module.
The camera has special markings to help ensure it is fitted correctly.
Given that the height at which the camera module is fitted depends
on local factors, we cannot recommend an optimum mounting height.
A mounting height of 1.5 m to 1.6 m has been a good rule of thumb
in the past.
For the automatic system to work properly, the light sensor should be
fitted at a location where daylight can reach it. If you want to fit the
light sensor to your existing front plate, a 3 mm hole will be needed.
See the drawings for the exact dimensions of the individual modules.

POSSIBLE SETTINGS

The outdoor station offers the following possibilities to set the system
to your personal circumstances:
Volume of the outdoor station
The potentiometer (9) is used to set the volume on the outdoor station.
To set the highest volume, turn the potentiometer carefully clockwise
as far as possible. Reduce the volume by turning in an anti-clockwise
direction.