Technical specifications of the gas control system used in the freestanding stove
PRESSURE DROP/CAP ACITY
FUEL
PRESSURE DROP/CAP ACITY
ADJUSTMENT RANGE
ADJUSTING THE REGULATOR
MOUNTING POSITION
MAXIMUM PRESSURE OF INPUT GAS
MAIN GAS INLET CONNECTION
CONTROL BURNER CONNECTION
DISCHARGE OF THE MAIN GAS INLET
AND OUTLET
MAXIMUM TIGHTENING TORQUE
THERMOCOUPLE /BREAKER BLOCK
IGNITION
ALLOWABLE TEMPERATURE LIMIT
The gas control system used in the freestanding stove PANTHER MERLOT series meets the
requirements for appliances burning gaseous fuels in Directives 2009/142/EEC and DIN EN 298, DIN
EN 126, DIN EN 13611. The system can be supplied with a gaseous fuel, second and third family
according to PN-EN 437:2003+A1:2009 and PN-EN 613:2002+A1:2004.
First, make sure that the connected device is intended to be supplied with the type of gas contained
in the gas installation. All the necessary information about the required parameters of the gas can
be found on the nameplate of the stove. Before connecting the gas supply pipes, it is necessary to
purge them to remove metal filings and other ontaminants from their interior. The automatic gas
control should be protected from moisture and dust. These factors may cause irreparable damage to
individual components. Gas supply pipes to the stove should be equipped with a ball valve of 1⁄2 inch
in diameter. Individual elements of gas installation cannot be sealed using a Teflon tape or PTFE tape
(Please use the sealing elements supplied with the unit). If the gas installation needs to be connected
to a settler, install it according to Fig. 12. The settler protects the controller from gas contaminants.
2009/142/EEC oraz DIN EN 298, DIN EN 126, DIN EN
13611
Gaseous fuels of the firs , second and third fami-
ly, according to PN-EN 437:2003+A1:2009 PN-EN
613:2002+A1:2004
2,5 mbar for 1,2 m
/h
3
Class C, according to EN 88
5 do 40 mbar (0,5 do 4 kPa)
the module cannot be mounted with the breaker block
downwards. The control position can be adjusted in the
range from 0° to 90° relative to its home position
50 mbar (5 kPa)
Reducing nipple 1/2'' na 3/8''
M10x1 for a pipe of 6 mm
From the side or bottom
nlet and outlet connection
connection:15 Nm
M10x1, M9x1, M8x1
Piezoelectric ignition
Controller: 0 °C to 80 °C
Receiver without batteries: 80 °C
Odbiornik z bateriami: 55 °C
Pilot: 60 °C
Przewód zapłonowy: 150 °C
/
": 35 Nm Control burner
3
8
49