Installation of the control system
NOTE!!!
The device with its gas control system can be installed only with its factory settings. At this
stage, do not install the battery in the receiver. Earlier connecting to a power supply may cause
damage to the electronics system.
NOTE!!!
Individual gas control system components, connect according to the diagrams provided in this
manual.
The standard gas control system includes a MaxitrolMertik GV60 controller and a B6R-R8U receiver
from which an antenna enables operation of the device using a remote control. Remote control gas
components should be installed in the connection box. The connection box must be installed in an
accessible place for possible repair or replacement of individual components of the system. Exposure
of the electronic system to temperatures exceeding 60°C will result i n irreparable damage. Elements
of the control system should be installed in a place where the temperature does not exceed 25°C.
The maximum distance between the contr ol box and the gas stove is determined by the length of
the cables connecting the GV60 gas control with the electrode and thermocouple. Do not extend the
cables provided with the unit, as this may affect the control system malfunction.
Keep in mind not to put the ignition cable too close to the metal parts. Contact of the ignition cab-
le with the receiver housing can cause damage. Components of the system may not be exposed
to moisture, dust, and factors affecting the formation of corrosion. Freestanding STOVE PANTHER
MERLOT can operate only with the gas control system supplied with the unit. When replacing
individual components of the system, use only original parts available for purchase from the
manufacturer. Plugs of individual wires are chosen in such a way as to prevent incorrect connection
of components.
Magneto
Magneto wire
Figure 6. The wiring diagram of the
system components for gas control
Control
burnner
Interrupter block
GV60 controller
Receiver
8 core cable