Kratki PANTHER MERLOT Manuel D'utilisation Et D'installation page 43

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Figure 4. The minimum distance of the gas stove from the flammable housing omponents.
Connecting the device using a coaxial combustion air system
Installation must be in accordance with local building regulations. It is recommended to pass the
flue pipe th ough the wall of the building by the use of 1 meter vertical section, angle 90° and a max-
imum of 3-meter horizontal section. In the case of stoves with linear LPG burners, it is recommended
to use a 1 meter vertical section, a 90° elbow and a maximum of 2 meters of a horizontal section. The
connection between the device and the coaxial cable must be sealed with high-temperature silicone.
All ducts cannot be insulated. In the case of flue passage th ough the external wall of the building:
• Install the system in accordance with the applicable regulations, including any difficulties elated
to the wind pressure on the terminal.
• In the case of flammable alls, provide an additional distance of 5 cm between the wall and the
outer surface of the coaxial cables. The remaining space is to be filled with p otective insulation
against the ingress of moisture into the building.
• If the flue pipe is close o combustible walls, protect them with thermal insulation at a minimum
distance of 25 cm.
• Installation of the coaxial system installation begins at the outlet of the stove 1 meter vertical
section (the minimum height).
• Individual elements of the system should be connected by means of special clamps to ensure
proper tightness.
• In the case of necessity, individual components of the system should be stabilized using wall
mounts.
43

Publicité

Table des Matières
loading

Table des Matières