The discharge current is always automatically adjusted to the capacity of the accu-
mulator and cannot be adjusted. Only the final discharge voltage can be set in dis-
charge mode.
In automatic discharge mode, the discharge voltage is 2.00V.
For standard lead accumulators, the final discharge voltage can be set from 1.80 to
2.10V in steps of 10mV; a value of 2.00V is recommended.
For lead gel and lead fleece accumulators, the final discharge voltage can be set
from 1.70 to 2.00V in steps of 10mV; a value of 1.90V is recommended.
"SET DIS-VOLTAGE "
" 1.75V
In the WINTER programme it is necessary to determine the pause period to be main-
tained between the cycles. It can be set from 3 to 30 days; a pause of 7 days is rec-
ommended.
"SET BREAK
" 7 DAYS BREAK
Now the programme starts.
CAUTION!
If any of the parameters has not been entered correctly, the lead accumulator is to be
disconnected immediately and then connected anew. All parameters are to be
entered again!
During the start, the flashing arrow indicates whether the corresponding accumulator
is charged or discharged at the moment. The CHA, CYC and ALV programmes start
with a charging process, whereas the CHK and WIN programmes start with a dis-
charging process.
All available data of the accumulator are displayed.
There are two display types provided. These two display types are selected via the
UP and DOWN keys. With the OK button pressed, the two displays are shown alter-
nately approx. every 4 seconds.
"CHA S>C= 17.4mAh"
"St12V D=
0.0mAh"
"23° C >U= 12.109V"
"00:01 I = 0.200A"
"
"
"