Gaggenau AT 400-101 Notice De Montage page 12

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
A
Installation in work surface 60 cm deep
with short drawers
Work surface depth 60 cm, combination with
Gaggenau cooktop CE/CI490. Cabinet
depth 55 cm, short pull-out drawers. Shallow
depth for fixing front panel (access to the
front of the fan housing must remain possi-
ble).
B
Installation in work surface 60 cm deep
with swing doors
Work surface depth 60 cm, combination with
Gaggenau cooktop CE/CI490. Cabinet
depth 55 cm, swing doors. Cabinet shelves
and rear wall must remain detachable.
Reposition the lower hinges on swing doors.
C
Fitted rear panel placed upon work surface
Work surface depth 65 cm, combination with
Gaggenau cooktop CE/CI490, fitted rear
panel behind cooktop. Worktop cutout
depends on thickness of rear panel. Cabinet
depth 55 cm, short pull-out drawers. Shallow
depth for fixing front panel (access to the
front of the fan housing must remain possible).
D
Combination with standard depth hob
Work surface depth 75 cm, combination with
Gaggenau Vario 400 (VC, VF, VI, VK, VP,
VR only) or electric cooktop. Cabinet depth
55 cm, pull-out drawers.
E
Installation between two cabinets with
continuous work surface
Work surface depth 75 cm, combination with
electric cooktop. Open storage shelves
under cooktop. Base and rear wall must
remain detachable. Support fan housing with
furniture support AA 409-400/430.
F
Combination with built-in oven 45/48 cm
high
Work surface depth 75 cm, combination with
electric cooktop and Gaggenau oven EB
385/388 or compact oven (must not exceed
the maximum allowed cabinet temperature).
Cabinet depth 55 cm. Use telescopic exten-
sion AA 409-900/930 between upper part of
table ventilation and fan housing.
G
Combination with built-in oven 59 cm high
Island oversize depth, combination with elec-
tric cooktop and oven (must not exceed the
maximum allowed cabinet temperature). 2x
cabinet depth 55 cm, short pull-out drawers.
Telescopic extension
AA 409-900/930 can be used.
H
Combination with Vario 400 and built-in
oven 48 cm high
Island oversize depth, combination with
Gaggenau Vario 400 (only VC, VI, VP, VR)
and oven EB 385/388. 2x cabinet depth 55
cm, short pull-out drawers. Telescopic exten-
sion AA 409-900/930 can be used.
12
Dimensions for air recirculation
mode – figure 3
All depths are measured from the rear edge of the
upper part of the table ventilation. Make allowances
for a possible fitted rear panel.
If necessary, reposition the lower hinges on swing
doors.
The opening in the lower cabinet shelf may be
increased as long as the free minimum cross-
section of 1800 cm
2
is maintained.
The final position of the base cabinet must be taken
into account when measuring the cut-out in the
base cabinet. All depths are measured from the rear
edge of the upper part of the table ventilation.
The exhaust outlet in the plinth should be as large
as possible (min. 720 cm
The location of the exhaust outlet in the plinth is
customer-defined. The air exhaust grille AA 010-
410 can be used to cover the exhaust outlet in the
plinth.
For island: Alternatively turn fan 180°.
The remaining surface of the worktop (min. 50 mm)
between the recesses must be reinforced with a
support. Furniture supports AA 409-400/430 can
be used for this and to stabilise the cabinet.
Dimensions air exhaust mode –
figure 4
All depths are measured from the rear edge of the
upper part of the table ventilation. Make allowances
for a possible fitted rear panel.
If necessary, reposition the lower hinges on swing
doors.
Attachment of exhaust pipe directly in the blower
housing onto the blower outlet.
For island: Alternatively turn fan 180°.
The remaining surface of the worktop (min. 50 mm)
between the recesses must be reinforced with a
support. Furniture supports AA 409-400/430 can
be used for this and to stabilise the cabinet.
Cabinet dimensions wall situation –
figure 5
A: Cut-out min. 1800 cm
B: Cut-out ø 165 mm for exhaust pipe if required
All depths are measured from the rear edge of the
upper part of the table ventilation. Make allowances
for a possible fitted rear panel.
2
) to minimise draughts.
2
for air recirculation

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

At 400-131

Table des Matières