Valeo Thermo 230 Notice De Montage page 56

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical connections
10.5. Water Temperature Control Thresholds:
Heater
Auxiliary heating
On
Thermo 230
Thermo 300
Thermo 350
10.5.1.
Pin Assignment of Cable Harness for Control Thresholds for Series
Thermo S 160 / Thermo S 230 / Thermo S 300 / Thermo S 350 / Thermo S 400:
Control unit function
Auxiliary heating
Parking heating
Economy setting 1
Economy setting 2
Terms:
Auxiliary heating:
Heater is operating, engine is operating
Parking heating:
Heater is operating, engine is off
Economy setting:
Control temperature is on a lower level
NOTE:
Auxiliary heating has priority over the economy setting!
For further information on the operating modes economy setting,
auxiliary heating and parking heating, refer to the Workshop Manual.
56
Parking heating
Off (CI)
On
78
85
70
on/off
Volt
Connector
on
24 V
X3
-
open
X3
on
24 V
X3
on
ground
X3
Economy setting
Off (CI)
On
Off (CI) CI
85
55
70
Pin
Comment
5
only in conjunction with parking heating
4
switch connecting wire to control unit
4
only in conjunction with parking heating
4
only in conjunction with parking heating
Thermo 230/300/350
Comment
= control idle
On/Off
= lower / upper threshold
Standard data record

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Thermo 300Thermo 350Thermo 230

Table des Matières