Annexe
RELAY
R
SERVICE
S
E+H SERVICE
E
INTERFACE
F
122
Clean = Chemoclean
(with Rel3 a. Rel4 only)
Timer
PID controller
LC °C =
limit contacter T
Select contact to
be configured
LC PV =
Rel1; Rel2; Rel3; Rel4
limit contacter O
R1
Selection of
Hold configuration
language
none = no hold
Cal
= during calibration
Eng; Ger; Ita;
S+C = during setup + calibration
Fra; Esp; Nel
Setup = during setup
S1
Software version
SW version
Sens = sensor
E1 (5)
Software version
SW version
Rel = relay
E1 (4)
Software version
SW version
MainB = main board
E1 (3)
Software version
SW version
Trans = transmitter
E1 (2)
Software version
SW version
Contr = controller
E1 (1)
Tag description
Entry of address
@@@@@@@@
Hart: 0 ... 15 or
PROFIBUS: 1...126
F1
Function R2 (5)
Selection of start pulse
switch on or off
int
= internal
i+ext = internal + external
ext
Off
On
i+stp = internal suppressed by external
R2 (5)
R251
Function R2 (4)
Setting of rinse time
switch on or off
Off
On
30 s
R2 (4)
R241
Entry of set point
Function R2 (3)
switch on or off
5,000 mg/l;
50,0 %SAT; 0...200%SAT
Off; On;
200 hPa;
Basic; PID+B
R231
R2 (3)
Function R2 (2)
Entry of switch-on
switch on or off
temperature
Off
On
60 °C
R2(2)
R221
Function R2 (1)
Select switch-on
switch on or off
contact point
20,000 mg/l; 0...20 mg/l
200,0%SAT;0...200%SAT
400 hPa;
Off
On
2
R2(1)
R211
Manual hold
Off
S2
Serial number
Hardware version
is displayed
HW version
E151
E152
Serial number
Hardware version
is displayed
HW version
E141
E142
Serial number
Hardware version
is displayed
HW version
E131
E132
Serial number
Hardware version
is displayed
HW version
E121
E122
Serial number
Hardware version
is displayed
HW version
E111
E112
F2
Liquisys M COM223/253
= external
R252
Setting of
pause time
360 min
0 ... 999 s
1 ... 7200 min
R242
R243
Entry of
control gain K
p
0...20 mg/l
1.00
0.01 ... 20.00
0...400 hPa
R232
R233
Entry of switch-off
temperature
-10 ... 60 °C
60 °C
-10 ... 60 °C
R222
R223
Select switch-off
contact point
20,000 mg/l; 0...20 mg/l
200,0%SAT;0...200%SAT
0...400 hPa
400 hPa;
0...400 hPa
R212
R213
Entry of
hold dwell period
On
10 s
0 ... 999 s
S2
S3
Module ID
is displayed
E154
E153
Module ID
is displayed
E143
E144
Module ID
is displayed
E133
E134
Module ID
is displayed
E123
E124
Module ID
is displayed
E113
E114
A0027496-FR