The electrolysis cell is made of a transparent polymer in whose interior the electrodes are placed. The electrolysis cell must be always
installed indoors and after the pool filter, and after any other equipment that may be present (heat pumps, control systems, etc.).
The installation of the cell should allow easy access to the installed electrodes by the user. It is highly recommended to install the
electrolysis cell in a place of the pipe that can be easily isolated from the rest of the installation by two valves, so that the tasks of
maintenance can be carried out with no need of partial or total draining of the swimming pool.
Where the cell is installed on a by-pass (recommended option), a valve to regulate the flow must be introduced. Prior to installation,
please consider the following commentaries:
Flow direction marked in the cell must be respected. Recirculation system must guarantee the minimum flow
stated in the Table of Technical Specifications for each model
Flow
The system flow detector activates if there is not recirculation (flow) of water through the cell or if flow is very
FLOW
DETECTOR
low. If electrolysis gases are not properly removed through the electrolysis cell, the generated gas bubble
(GAS)
electrically isolates the auxiliary electrode (electronic detection). Therefore, when locating the electrodes in
the cell, the level sensor (auxiliary electrode) will have to be located in the higher area of the cell. The safest
orientation is shown in the recommended installation diagram.
GAS
AGUA
CRITICAL WATER
LEVEL
WARNING: if the in-out valves of the electrolysis cell are closed simultaneously, the flow detector (gas
detector) will not work correctly, with the consequent risk of cell breakdown. Although this situation is
extremely unusual, it can be easily avoided once the equipment has been installed, by locking at
opened position the return valve to the swimming pool, so it cannot accidentally be manipulated.
Other configurations would only be acceptable in the case that they allow for detection of gas bubbles when water flow through
the cell is too low.
FLOW
DETECTOR
(GAS)
RECOMMENDED Installation
FLOW
DETECTOR
(GAS)
ALLOWABLE installation
The electrodes must be inserted in the electrolysis cell, fitting the
central electrode through the guides located at the quadrants of the
cell. (According models)
17
FLOW
DETECTOR
(GAS)
NOT ALLOWED installations
FLOW
DETECTOR
(GAS)