SecurAccess Compact PMR – User Guide
A switch allows the choice of the door latch activation with exit button duration (2,4,6,8,10 seconds).
(If all the dipswitch levers are OFF, the delay time will be 20 seconds).
SWITCH ACTIVATION
EXIT BUTTON
ON
ON
OFF
OFF
Door latch
NO driving contact
closed when off-hook. Up to
60VA 2A maximun
Power supply
4.7. Disabled feature
The disabled feature, when activated, generates both visible (enlighted colour icons) and audible
(digital voice announcement) signals.
This feature requires an external power supply (page 28) TRT3 24V DC/AC 1A (LPS) double
insulation. (sold by Depaepe SAS)
Exit button
Door latch
EXIT BUTTON DEL
(Only if the button is
equipped with
NO
Red
Terminal
COM
ON
10 S
8 S
6 S
4 S
2 S
Note :
Rock the switch facing the chosen duration to «ON »,
All other switches must remain "OFF"
When all switches are on « OFF » position:
Duration=20 seconds
42
)
DEL
Door latch
Activation duration