SecurAccess Compact PMR – User Guide
Power
supply
3.11. Time out for no answer
Same as for Chain dialling section (§12.7).
This setting is used in the chain dialling settings choice and for the automatic hanging up.
If chain dialling is activated, the SecurAccess COMPACT PMR will automatically dial the following
number stored into the depressed off-hook/memory button after the selected elapsed time before
next call.
If chain dialling is deactivated, the unit will automatically hang up.
Setting to modify
Elapsed time before next call
3.12. Conversation timer
Talking time can be limited by programming. When this feature is activated and the preset talk time is
elapsed, the SecurAccess COMPACT PMR will automatically hang up.
Proceed as shown below :
Setting to modify
Talk time duration
3.13. Changing the programming access code
Programming access code coming out from factory setting is : 0000
This code can be modified as indicated below:
or
Door latch
Code
0 8
Code
0 7
Setting choice
Factory settings are shown in grey
0 : 10 seconds
1 : 20 seconds
2 : 35 seconds (factory setting)
3 : 1 minute
4 : 5 minutes
Setting choice
Factory settings are shown in grey
Enter the number of minutes of talk time (from 0 up to 9).
Note : 0 = no limit (factory setting)
NC
NO
COM
39
Conf.
*9
Conf.
*9