A list of 3 numbers stored. Repeated dial selection is 0. In case of busy tone and (or) no answer, the
SecurAccess COMPACT PMR will dial the list of 3 numbers one time and will hang up.

3.8. Ringer

3 levels adjustment: off-low-high and 3 melodies selection. Adjust as shown:
Setting to modify
Ringer level
Ringer melody

3.9. Automatic answering

An auto answer mode can be activated for calling a party standing close to the SecurAccess
COMPACT PMR or to enter the remote programming mode. The SecurAccess COMPACT PMR will
automatically go off-hook after a pre programmed number of rings:
-
From 1 up to 9 rings when automatic off-hook selection is activated
-
After 30 rings otherwise.
Setting to modify
Auto answer

3.10. Door latch activation and power schematic

The SecurAccess COMPACT PMR is fitted with a NO/NC driving contact for a remote activation of a
door latch electrical relay.
Following settings can be chosen by local or remote programming:
1. Activation or deactivation of the door latch
2. Activation duration
3. 4 digits access code selection (up to 6 different access codes, Note: 0000 will not work)
4. Fast opening selection
Setting to modify
Door latch activation
Activation duration
1
st
access code
2
nd
access code
3
rd
access code
4
th
access code
5
th
access code
6
th
access code
Fast opening with « 0# » ou « 0* »
NO: Normally open
NC: Normally close
COM : COMMON
Code
Setting choice
Factory settings are shown in grey
0 3
Low : 0 - High : 1
0 4
0 : ringer off
1 : Melody N°1
2 : Melody N°2
3 : Melody N°3
Code
Setting choice
Factory settings are shown in grey
0 5
Enter the number of rings before auto answer (0 up to 9)
Note: 0 = feature deactivated
3 = factory setting
Code
Setting choice
Factory settings are shown in grey
6 0
0 : activated (factory setting)
1 : deactivated (Door latch not active)
6 1
Enter the number of seconds (from 1 up to 9 seconds).
factory setting = 2 seconds
6 2
Enter a 4 digits code, (0000 not allowed)
6 3
Enter a 4 digits code, (0000 not allowed)
6 4
Enter a 4 digits code, (0000 not allowed)
6 5
Enter a 4 digits code, (0000 not allowed)
6 6
Enter a 4 digits code, (0000 not allowed)
6 7
Enter a 4 digits code, (0000 not allowed)
6 8
0 = deactivation (factory setting) - 1 = activation
Door latch
NC/NO contact
Up to 60 VA and 2A maximum