7. p
rotEctivE Functions oF thE spEEd controllEr
Undervoltage protection
The speed controller automatically "detects" the number of cells of the connected LiPo battery,
if it has 2, 4 or 6 cells.
We urgently recommend entering the number of cells manually though!
If the voltage for the LiPo battery drops below the programmed threshold value for more than 2
seconds, the speed controller will turn off the power supply to the motor. If there is not control
signal for 10 seconds, the speed controller will turn off the power supply to the motor. The red
LED will blink repeatedly, each time twice in rapid succession.

Overheating protection

If the temperature of the speed controller exceeds the factory-programmed value for more than
5 seconds, the speed controller will turn off the power supply to the motor.
The overheating protection can be switched off for racing operation!
Signal loss
If there is not control signal for 0.2 seconds, the speed controller will turn off the power supply
to the motor.
Blocking protection
If foreign matter blocks the drive train or the motor itself, the speed controller will turn off the
power supply to the motor.