Correct operation of the appliance is only guaranteed for pumps and valves approved by La Nordica. La Nordica is not liable for any
improper use of the appliance.
WARNING: In any case, the power cable has to be replaced by authorised personnel ONLY (entitled by La Nordica): authorised
dealers and/or fitter.
ATTENTION: the feeding cable must not be in contact with hot parts - MAX 75 °C.
See Chapter DISPLAY CONNECTION.
7.4.

FLOW CHART - MENU

LANGUAGE
BUZZER
ON - OFF
SET DEGREES
°C- F
DISPLAY
10 - 100%
TECHNICAL
SETTINGS
SYSTEM
( PR06 = Off )

8. FLUE

Essential requirements for correct appliance operation:
the internal section must preferably be circular;
the appliance must be thermally insulated and impermeable and built with suitable materials which are resistant to heat, combustion
products and any condensation;
there must be no narrowing and vertical passages with deviations must not be greater than 45°;
if already used, it must be clean;
the technical data from the instruction manual must be respected;
If the flues are of a square or rectangular section, the internal edges must be rounded with a radius of not less than 20 mm.
For the rectangular section, the maximum ratio between the sides must be ≤ 1.5.
A section which is too small causes a reduction in draught. A minimum height of 4 m is advisable.
The following materials are FORBIDDEN and compromise the good operation of the appliance: asbestos cement, galvanised steel, rough
and porous internal surfaces.
The minimum section must be 4 dm
dm
(for example 25x25 cm) for appliances with a diameter of more than 200 mm.
2
28
ITALIANO
ENGLISH
FRANCAIS
ESPANOL
DEUTSH
SETTINGS FACTORY
CODE 44
TEST OUTPUTS
STATUS Stove
PRODUCT
CODE 33
PR08 BOILER (On / Off )
PR09 SET BOILER Max
PR10 SET BOILER Min
PR11 PUFFER ( On / Off
PR12 thermal differential to PUFFER On (5 - 12°C) Default = 7°C
PR13 thermal differential to PUFFER Off (3 - 8°C)
Picture 1 at page 94
shows some example solutions.
(for example 20x20 cm) for appliances whose pipe dimensions are less than 200 mm, or 6.25
2
TERMOROSA READY DSA 2.0 - TEMOROSA XXL READY DSA 2.0
TEST OUT 1
TEST OUT 2
TEST OUT 3
I1= xx°C
Heating device
(
probe)
I2= xx°C
PUFFER
(
probe)
I3= xx°C
BOILER
(
probe)
I4= On / Off
(Flow switch)
0 = Heating device DSA
PR06
1 = All Inclusive
2 = WATER CONNECTION KIT
Default = 60°C
( 47 - 70°C )
Default = 30°C
( 30 - 46°C )
)
Default = 5°C
PR01 CIRCULATOR 1 Threshold OUT 1 (55- 65°C)
Default = Heating device 60°C
PR02 CIRCULATOR 1 Delta OUT 1
(1 - 5°C)
Default = 5°C
PR03 CIRCULATOR 2 Threshold OUT 2 (65 - 75°C)
Default = Heating device 70°C
PR04 CIRCULATOR 2 Delta OUT 2
(1 - 5°C) Default = 5°C
PR05 ANTIFREEZE Threshold
(2 - 10°C)
Default = 5°C
7097503