ChefLine FLAME 4 Manuel D'instructions Et D'utilisation page 91

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
3. Outlet pressure:
Connect the pressure gauge to the outlet pressure tap (4-Pout) via the special hose, once the relative
sealing screw has been removed.
After the pressure gauge has been connected, open the gas shut-off valve (set up in the system) and switch
on the burner (start the oven).
Measure the outlet pressure and check that the values correspond to what is shown in the table. The
minimum pressure is obtained when the burner operates at its lowest setting (standby); the maximum
pressure is obtained when the burner operates at maximum power.
The outlet pressures (minimum and maximum) are preset by the manufacturer according to the oven's gas
installation type.
If it becomes necessary to make adjustments, only then should you proceed as indicated below.
4. Maximum Pressure:
Turn on the oven in maximum pressure mode (green control panel switch [B] positioned on MAX).
Tighten the outlet nut [C] to increase the pressure and loosen it to decrease the pressure. 10 mm spanner.
5. Minimum Pressure:
Put the oven in minimum pressure mode (green control panel switch [B] positioned on MIN).
Whilst keeping the nut [C] locked, tighten the screw [D] to increase the pressure and loosen it to decrease
the pressure. 6x1 slotted screwdriver.
Reposition the modulator's plastic cap.
!
Warning: The cap [E] must be repositioned in order for the modulator to work properly.
To check the pressures, compare the data obtained with the values shown in the following tables.
Technical data table 1 - FLAME 4 nominal data
Pressione
nominale
Tipo
ingresso
di gas
Nominal
Gas
inlet
type
pressure
(mbar)
G20
20
G20
25
G25
20
G25
25
G25.1
25
G25.3
25
G30/G31
28-30/37
G30, G31
50
G30, G31
37
Portata
Portata
termica
termica
nominale
ridotta
Nominal
Reduced
heat
heat
input
input
(kW)
(kW)
14
8
14
8
14
8
14
8
14
8
14
8
14
8
14
8
14
8
Pressione
Pressione
all'uscita
all'uscita
valvola
valvola
(al MAX)
(al MIN)
Valve
Valve
outlet
outlet
pressure
pressure
(at MAX)
(at MIN)
(mbar)
(mbar)
10
3.2
10
3.2
15
4.5
15
4.5
17
5.2
14
4.0
28
9
28
9
28
9
Consumi del
gas al MAX
(con il potere
calorifico
Regolatore
inferiore)
di pressione
Gas
Pressure
consumption
regulator
at MAX
(with net
calorific
value)
3
1.481 m
/h
3
1.481 m
/h
3
1.722 m
/h
3
1.722 m
/h
3
1.720 m
/h
3
1.685 m
/h
1.104/1.088 kg/h
1.104/1.088 kg/h
1.104/1.088 kg/h
91
A
A
A
A
A
A
B
A
A

Publicité

Table des Matières
loading

Produits Connexes pour ChefLine FLAME 4

Ce manuel est également adapté pour:

Flame 6Flame 9

Table des Matières