Commissioning; Maintenance; Releasing The Transmitter; Dimensional Drawing - Gossen MetraWatt SIRAX V 644 Mode D'emploi

Convertisseur de mesure universel
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

11. Commissioning

Switch on the measuring input and the power supply. The
green LED flashes for 5 seconds after switching on and then
lights continuously.
The power supply unit must be capable of supplying
a brief current surge when switching on. The
transmitter presents a low impedance at the instant
of switching which requires a current I
≥ 160 mA for the version with a power supply
... I
start
range of 24 – 60 V DC/AC
≥ 35 mA for the version with a power supply
... I
start
range of 85 – 230 V DC/AC

12. Maintenance

No maintenance is required.

13. Releasing the transmitter

1. Rotate the quick release screws 90°.
2. Withdraw the plug-in module.
1.
Fig. 9. Withdraw the module from the base.
30
of ...
start
or
2.

14. Dimensional drawing

150.7
135.7
Fig. 10. Universal transmitter SIRAX V 644.
+0
15
18
– 0.5

Publicité

Table des Matières
loading

Table des Matières