Electrical installation

Power supply
Model-No.
6..... .. 2 .. ....
6..... .. 1 .. ....
Max. rated
power
Circuit breaker I
RCCB
Protection type IP X4
Protection class 1
Position of electrical connection
180 mm
7 1/8"
90 mm
3 1/2"
Pre-installation
> Lay a permanent power supply line:
Please observe the position of the electri-
cal connection
Leave at least 800 mm (31 1/2") of feed
cable exposed
> Install circuit breaker
Connect a separate upstream circuit
breaker
Connect an upstream residual current
device (RCD) separating all poles
33
Connecting the cable (Diagram 33)
> Please observe the L, N and PE
conductors.
35
Installing junction box (Diagram 35)
> Fix the junction box in the Wall-mounted
WC in the designated place.
SensoWash_MAL_WWC+Montageset#100691_56918/16.12.3
220 – 240 V 50/60 Hz
100 - 120 V 50/60 Hz
1.65 kW
= 16 A
N
I
= 30 mA
N
90 mm
3 1/2"

Water installation

Cold water
DN 10 (⅜")
Water pressure 0.07 - 0.75 MPa
(0.7 - 7.5 bar)
Water hardness max. 2,4 mmol/l
NOTE!
> Install a water water softener with water
hardness ≥ 2.4 mmol/l (≥ 14° dH and/or
24° fH).
DANGER!
Health risk and potential product damage.
> Supply the Shower WC with cold drinking
water from the main water system.
> Do not connect any waste water, grey
water, industrial water, sea water or other
untreated or semi-treated water.
Pushing the water hose through the
6
ductwork into the front-wall element
(Diagram 6)
NOTE! Avoiding any malfunctions!
> Only use the reinforced water hose from
the installation kit.
Shutting off the water supply
10
(Diagram 10)
NOTE! Avoiding water damage.
> Shut off the water supply prior to the
water installation.
7