4. Mounting the unit

By using the fastening set Order No. 92569 the filter unit must be firmly mounted in the vertical
position by means of the fixing angle and included screws in a suitable place. Ensure that the unit is
mounted in a manner to protect against outside mechanical influence such as bumping or shaking.
The filter may also be mounted vertically and firmly to compressed air lines without mounting to the
wall (mount air lines accordingly).
Remove plastic plug at the air inlet (5) and screw in fitting. Ensure tight fit and tension free assembly.
For maintenance, it is recommended to include shut-off valve with removable coupling at the air inlet
(a coupling may also be put at the air outlet).
Connect one end of the condensate drain hose (10) on the brass connection piece and the other end
into an appropriate condensate storage container. Make sure that the container will not tip and the
hose will not jump out when condensate is blown.
Attention! Condensate is hazardous waste.
5. Combination filter assembly
1.
0/444: Manifold with 2 ball taps may be connected
to the filter unit by means of the existing detachable
joint fitting.
2.
0/484 and 0/494: Manifold with 2 ball taps and
the corresponding additional filter module may be
connected to the filter unit by means of the existing
detachable joint fitting.
3.
Equipping an already existing filter unit of the 0/400
series with an activated charcoal filter 0/464 requires
the following parts:
1 x filter unit 0/464 (Order No. 92241)
1 x joint fitting cpl., detachable (Order No. 95000)
The joint fitting is fixed between the outlet module of
the existing filter unit and the filter unit 0/464 (remove blind plug) and glued in with Loctite 242.
6. Pressure regulation valve
The required working pressure can be adjusted at
the regulating valve (1 to 3). If air escapes at the
vent hole at the rear of the fixing nut (2) or the valve
does not function properly, the pressure regu-
lation valve must be disassembled, cleaned and
inspected. If necessary, the diaphragm (order no.
2949) and the pressure regulation valve rod (order
no. 84764) have to be replaced or regreased with
grease for spray guns (Order No. 48173 or 10009
(unit of 6 tubes)
VIII.4
95000
10934
Thread slightly
greased with
OKS 470
0/444
0/484
10934
0/494
96743
Diaphragm
Pressure regulation valve
rod
„O" ring slightly greased
with OKS 470

Publicité

Table des Matières
loading

Table des Matières