Instructions for use and maintenance SATA Modular Filter Series 0/400

2. System operation

The SATA 0/400 modular filter line may be used for purifying compressed air, non-toxic and non-combu-
stible gaseous media. It separates the solid, liquid and partially gaseous components from the air flowing
through the unit. Without a filter, these components would lead to negative effects in regard to the follow-
up devices resp. the work results achieved with it as well as the worker health protection.
2.1. Stage Filter (I):
The stage 1 filter stage separates particles larger than 5 mm as well as condensation and oil. A
built-in pressure regulator (nos. 1-3) allows precise air adjustments of the outlet pressure without
fluctuations. When condensation in the filter tube (no. 7) reaches a certain level, a built-in automatic
condensate discharger (no.9) opens, pressurizing the condensate and forcing it out through the
drain hose (no. 10); a small non-drainable portion is left inside.
Construction identical with:
92262
0/424L for air line installation
92221
0/424 with manifold
92254
0/414L for air line installation, without
pressure regulator and gauge
92213
0/414 with manifold, pressure regulator
and gauge
2.2. Stage Filter (II):
A filter cartridge in stage 2 filter separates tiny particles according to the filtration capacity of the
cartridge used.
Filter type 0/434 Filtration capacity 0,01mm, 99,998 % separation
The construction of the activated charcoal filter 0/464 is identical to the fine filter 0/434 (0/434L).
The 0/464 filter contains an activated charcoal cartridge (Order No. 85373). All activated charcoal
filters must be preceded by a condensate discharge unit and a fine filter stage.
Construction identical with:
92270
0/434L for air line installation, 99,998 %
separation
92239
0/434 with manifold, 99,998 %
separation
92247
0/464 with activated charcoal cartridge and
manifold with two ball taps
2.3. Manifold Order No. 59295 (III):
The manifold is equipped with two ball taps with outside thread G1/4a for connecting two further
compressed air tools.
VIII.2