Technical Data And Specifications - SATA 0/400 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Instructions for use and maintenance SATA Modular Filter Series 0/400
2.4. Filter cartridges
Type:
Sinter filter cartridge
Sinterd bronze 5 µm,
surface area 100 cm², solvent
regenerable
Replacement interval every
six months
Order No. 22160
In case of extreme contamination, filters should be checked and, if necessary, replaced more frequently.
The sintered bronze filter (8) and the filter housing tube (7,11) must be cleaned every six months at the
latest, if necessary, replace sintered bronze filter cartridge. Saturated filter cartridges bear the danger of
functional defaults during painting resp. affecting the painter's health while using supplied-air respirator
systems.

3. Technical data and specifications

- Air inlet G 1/2 inside thread
- Maximum inlet operating pressure 15 bar/225 psi; 1,5 MPa
for 0/434; 0/464 = 10 bar/150 psi; 1,0 MPa
- Maximum outlet operating pressure 10 bar; 1,0 MPa
- Air flow rated at 3600 NI/min (129,6 cfm) at 6 bar/90 psi
- Max: ambient temperature 120° C (248 F) with activated charcoal unit max:
ambient temperature 60 ° C (140 F)
Weight:
0/414
0/414L
0/424
0/424L
0/434
0/434L
0/464
Combination filter
0/444
0/444L
0/474
0/484
0/494
Fine filter cartridge, Polypropy-
lene Micro Fibre layer Surface area
300 cm² Filtering capacity 0,01 µm
99,998 % separation,
non-regenerable
Replacement interval every
six months, at the latest when
the maximum pressure diffe-
rence between inlet and outlet
pressure is 1 bar/14.5 psi
Order No. 81810
=
2,2 kg
=
1,5 kg
=
2,7 kg
=
2,0 kg
=
2,3 kg
=
1,6 kg
=
2,3 kg
=
4,3 kg
=
3,5 kg
=
3,9 kg
=
5,9 kg
=
6,6 kg
Activated charcoal cartridge
non-regenerable
Replacement interval every
three months
Order No. 85373
VIII.3