Voltage Check List - Gallagher 3E1803 110V Notice D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Gallagher 3E1803 110V Energizer User Manual

VOLTAGE CHECK LIST

Unplug the energizer from
the power supply and
remove the fence wire from
the red (FENCE) terminal.
Plug energizer in again and
check. Is the voltage across
the terminals greater than
5000 volts?
Test the ground
system.
Is the ground
voltage more
than
200 volts?
Improve the ground
system: add
galvanized ground
rods to the ground
system un l the
ground voltage is
200 volts or below.
Is the energizer opera ng?
Yes
Yes
Yes
No
Energizer needs
to be serviced.
No
1. Check the electrical connec ons
are secure e.g. from the fence to the
red (FENCE) terminal, from the ground
system to the green (GROUND)
terminal, at gates etc.
2. Check the voltage on the fence
every 100 . Note if the voltage is
dropping. The closer to a short, the
lower the voltage reading will be.
Become aware of things that cause
shorts and always be on the lookout
for: stray pieces of wire on the fence,
heavy undergrowth, cracked or
broken insulators, broken wires etc.
Voltage Checklist
No
Test the power
supply.
If the power
supply is
OK then the
energizer needs
to be serviced.
13

Publicité

Table des Matières
loading